Y-4
Y-4
Air Bleeding Procedure
31
WY05-5000E
1.3 Variable piston pump (when the tank
pressurization tool is used)
[NOTICE]
Adjust the pressure setting of the tank
pressurization tool to 15 kPa (0.15 kgf/cm²) (2.2 psi).
During work, check the pressure gauge so that the
pressure is within 15 kPa (0.15 kgf/cm²) (2.2 psi).
Never actuate the hydraulic cylinder with the tank
pressurization tool attached.
1. After replacing the hydraulic pump or the hydraulic
oil, check that the oil level is at the specified level.
2. Remove the air breather on the top of the
hydraulic oil tank and attach the tank
pressurization tool.
3. Slowly loosen the air-bleed plug (G1/4) and let the
oil with bubbles flow out.
4. After making sure that flowing oil contains no
more bubbles, tighten the air-bleed plug while the
hydraulic oil is flowing out.
5. While the tank is pressurized, turn the PTO switch
OFF and start the engine. After idling the engine
for 5 seconds, turn the PTO switch ON and OFF
repeatedly and quickly and check for any
abnormal noise.
6. If any abnormality is found, bleed the hydraulic
pump again.
7. If there is no abnormal noise, turn ON the PTO
switch and idle the engine for 5 minutes with no
load.
8. During the operation, check for any abnormal
noise or heat of the hydraulic pump and oil leaks
from the whole system.
9. After checking that there is no abnormality,
remove the tank pressurization tool on the top of
the hydraulic oil tank and attach the air breather to
the original position.
10. Now the bleeding is complete.
If the hydraulic pump has been replaced, run-in
the pump.
1.4 Tank pressurization tool
1. Valve assy (A) (Part number : 329-806-59100)
1.5 Other (cylinder)
1. When bleeding the cylinder thereafter, make the
engine speed medium (1000 min
-1
or less).
2. When the oil temperature needs to be increased
for adjusting pressure, perform the work after
eliminating air bubbles inside the oil tank by air
bleeding.
△
0
345-800-00500
Содержание GR-1600XL
Страница 1: ......
Страница 8: ...7 WA04 5330E 6 Group index System Diagrams Data Adjustment and Checks Y Z Y Z ...
Страница 28: ...14 WY02 2020E Y 2 Y 2 Adjusting Pressure Hydraulic Pressure ...
Страница 30: ...16 WY02 2020E Y 2 Y 2 Adjusting Pressure Hydraulic Pressure ...
Страница 33: ...19 WY02 2020E Y 2 Y 2 Adjusting Pressure Hydraulic Pressure ...