Z- 4
WZ03-7602E
Electric Circuit (Upper) (Crane)
Z- 4
Z- 4
IWZ03-7183E03
19
19
5
344-125-66500
4.9 Electric circuit (AML, fix jib)
To circuit (crane, main)
1.25
To circuit (boom, fix jib)
Detector power supply (+5V)
SHIELD
Detector power supply (GND)
Boom angle input
SHIELD
Detector power supply (+5V)
Detector power supply (GND)
SHIELD
SHIELD
Slewing angle 1 input
Detector power supply (GND)
Detector power supply (+5V)
Slewing angle 2 input
Detector power supply (+5V)
Detector power supply (GND)
Elevating cylinder raising pressure input
Detector power supply (+5V)
Elevating cylinder lowering pressure input
Detector power supply (GND)
Main pressure input
(C01-012)
(C01-011)
(C01-010)
(C01-009)
(C01-008)
(C01-007)
(C01-006)
(C01-005)
(C01-004)
(C01-003)
(C01-002)
(C01-001)
SHIELD2A
1
2
3
1
2
3
SHIELD4
SHIELD5
SHIELD3
SHIELD2B
SHIELD3A
1
2
3
3
2
1
4
5
6
1
2
3
CN581
1
2
3
CN584
1
2
3
CN585
3
1
4
6
5
2
CN580
SHIELD3B
3
5
2
4
1
3
5
2
4
1
CN1595
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
CN1750
To circuit (crane, main)
(S03-AA) Y
(S05-007) W
(S05-007) W
(S04-024) W
(S04-024) W
(S02-018) W
(S02-018) W
(S04-AA) Y
(S04-AA) Y
(S05-AA) Y
(S05-AA) Y
(S01-AB) Y
(S01-AB) Y
(S01-016) B
(S01-016) B
(S02-AA) Y
(S02-AA) Y
AVS
(S02-AB) Y
(S03-023) R
(S03-023) R
(S03-021) W
(S03-021) W
(S05-009) R
(S05-009) R
(S02-019) G
(S02-019) G
(S01-015) R
(S01-015) R
(S05-008) B
(S05-008) B
(S01-013) W
(S01-013) W
(S01-AA) Y
(S02-017) R
(S02-017) R
(S02-020) B
(S02-020) B
(S04-026) R
(S04-026) R
(S04-025) B
(S04-025) B
(S03-022) B
(S03-022) B
R
W
B
+
-
R
W
B
+
-
R
W
B
+
-
1
2
3
4
5
6
7
8
9
10
11
12
13
14
1
2
3
4
5
6
7
8
9
10
11
12
13
14
CN888
1
2
3
4
5
6
7
8
9
10
11
12
13
14
CN887
B/1-
SB/1
R/1-
G/1-
Y/1-
B/2
GR/2-
R/2
G/2
Y/2
BR/2
L/2
SHIELD
Detector power supply (+5V)
Detector power supply (GND)
Boom angle detector (signal)
Pressure sender
(elevating cylinder, boom raising)
Pressure sender
(elevating cylinder, boom lowering)
Slewing angle detector
To circuit (boom, fix jib)
CN3
CN4
Pressure sender
(main pressure)
1
3-1
+5V
2
3-2
Ai1
3
3-3
AI2
4
3-4
AI3
5
3-5
AGND
6
3-6
SHIELD
7
3-7
+5V
8
3-8
Ai4
9
3-9
Ai5
10
3-10
Ai6
11
3-11
AGND
12
3-12
SHIELD
1
4-1
FG
2
4-2
+5V
3
4-3
Ai7
4
4-4
Ai8
5
4-5
AGND
6
4-6
SHIELD
1
2
3
4
5
6
7
8
9
10
11
12
CN653
1
2
3
4
5
6
CN654
Telescoping cylinder stroke
Boom retracting operation pilot pressure input
Boom extending operation pilot pressure input
AML-C {ESP}
SHIELD
Detector power supply (+5V)
Detector power supply (GND)
Telescoping cylinder stroke detector (signal)
Elevating pivot pin inserting solenoid valve
Jib lock pin retraction solenoid valve
Jib lock pin extension solenoid valve
PTO linked power supply (STD)
Jib lock pin extension solenoid valve
Jib stowed detection switch
Jib lock pin retraction detection switch
Two-blocking detection switch
Jib extension solenoid valve
Two-blocking detection switch
Working lamp switch linked power supply
Working lamp switch linked power supply
Jib lock pin retraction detection switch
Elevating pivot pin extracting solenoid valve
Jib retraction solenoid valve
Jib retraction solenoid valve
Jib stowed detection switch
Jib extension solenoid valve
PTO linked power supply (STD)
Jib lock pin retraction solenoid valve
R
W
B
+
-
R
W
B
+
-
M6_0.85-1.25
E001
Ground
SHIELD1A
1
2
3
1
2
3
SHIELD15
SHIELD14
3
5
2
4
1
SHIELD1B
1
2
3
CN1190
Pilot pressure sensor
(boom retracting)
1
2
3
CN1189
Pilot pressure sensor
(boom extending)
3
5
2
4
1
CN993
To circuit (boom, fix jib)
(S15-R) R
(S15-R) R
1.25
(S06-AA) L
(S15-B) B
(S15-B) B
(S06-016) B
(S06-016) B
(S14-B) B
(S14-B) B
(S15-AA) B/R
(S06-014) GR
W
(S06-014) GR
W
(S14-AA) Y
(S14-R) R
(S14-R) R
(S06-015) R
(S06-015) R
(S15-W)W
(S15-W)W
(S14-W)W
(S14-W)W
1.25
(S06-AB) L
Elevating pivot pin extracting solenoid valve
Elevating pivot pin inserting solenoid valve
Jib mounting / stowing signal
Jib mounting / stowing signal
output
output
output
output
output
[NOTICE]
1. If not specified, wire type is CAVS and wire size is 0.5mm
2
.
5
5
Applicable serial No. : FE5074--
5
Содержание GR-1600XL
Страница 1: ......
Страница 8: ...7 WA04 5330E 6 Group index System Diagrams Data Adjustment and Checks Y Z Y Z ...
Страница 28: ...14 WY02 2020E Y 2 Y 2 Adjusting Pressure Hydraulic Pressure ...
Страница 30: ...16 WY02 2020E Y 2 Y 2 Adjusting Pressure Hydraulic Pressure ...
Страница 33: ...19 WY02 2020E Y 2 Y 2 Adjusting Pressure Hydraulic Pressure ...