Y-5
Y-5
Adjusting Procedure (Electric)
41
WY04-2421E
3. Jib stowed detection switch (CN572)
Adjust the switch position so that the dimension A
becomes 4
+0.5
–
0
mm (0.16
+0.02
–
0
in) with the jib stowed.
(*1):
•
Apply a thread locking agent (ThreeBond 1401
or the equivalent) to the threaded section of
the switch.
•
Switch fixing nut tightening torque
: 40 to 50 N-m (4.1 to 5.1 kgf-m)
(2.95 to 36.9 ft-lbf)
[NOTICE]
Make sure that the orange LED lights up when the
switch is activated.
4. Jib lock pin retraction detection switch
(CN573)
Adjust the switch position so that the dimension A
becomes 30.5
+1
–
0
mm (1.2
+0.04
–
0
in) with the switch in
free position.
(*1):
•
Apply a thread locking agent (ThreeBond 1401
or the equivalent) to the threaded section of
the switch.
•
Switch fixing nut tightening torque
: 4 to 6 N-m (0.41 to 0.61 kgf-m)
(3.0 to 4.4 ft-lbf)
△
2
343-550-62000
△
2
343-550-62000
△
0
343-553-62000
△
0
343-553-62000
△
8
343-546-42000
△
6
343-543-42000
△
6
343-543-42000
△
8
343-546-42000
Содержание GR-1600XL
Страница 1: ......
Страница 8: ...7 WA04 5330E 6 Group index System Diagrams Data Adjustment and Checks Y Z Y Z ...
Страница 28: ...14 WY02 2020E Y 2 Y 2 Adjusting Pressure Hydraulic Pressure ...
Страница 30: ...16 WY02 2020E Y 2 Y 2 Adjusting Pressure Hydraulic Pressure ...
Страница 33: ...19 WY02 2020E Y 2 Y 2 Adjusting Pressure Hydraulic Pressure ...