FI SYSTEM DIAGNOSIS 4-33
5) Disconnect the ECM coupler.
6) Check the continuity between W/Bl wire
A
and terminal
7
.
7) If OK, then check the continuity between B/Br wire
B
and ter-
minal
T
.
IAPS lead wire continuity: Continuity (
)
09900-25008: Multi circuit tester set
09900-25009: Needle-point probe set
Tester knob indication: Continuity test (
)
Is the continuity OK?
Step 1 (When indicating P0105-L:)
1) Turn the ignition switch OFF.
2) Check the IAP sensor coupler for loose or poor contacts.
If OK, then check the IAP sensor lead wire continuity.
3) Disconnect the IAP sensor coupler.
4) Check the continuity between W/Bl wire
A
and ground.
5) Also, check the continuity between W/Bl wire
A
and B/Br
wire
B
. If the sound is not heard from the tester, the circuit
condition is OK.
YES
Go to Step 2.
NO
W/Bl wire shorted to VCC, or B/Br wire open.
1
!
ECM coupler (Harness side)
1
1
Содержание TU250X
Страница 1: ......
Страница 2: ......
Страница 41: ...PERIODIC MAINTENANCE 2 23...
Страница 213: ...EXHAUST SYSTEM 6 1 6 EXHAUST SYSTEM CONTENTS EXHAUST SYSTEM 6 2 REMOVAL 6 2 INSPECTION 6 4 INSTALLATION 6 4...
Страница 342: ...10 22 SERVICING INFORMATION SIDE STAND INSTALLATION 50 N m 5 0 kgf m 36 0 lbf ft 55 N m 5 5 kgf m 40 0 lbf ft...
Страница 369: ......
Страница 370: ......