11-8 EMISSION CONTROL INFORMATION
INSPECTION
• Check that air flows through the air inlet port to the air outlet
port.
• If air does not flow out, replace the PAIR control solenoid
valve with a new one.
A
Air flow
• Connect 12 V battery to the PAIR control solenoid valve termi-
nals and check the air flow.
• If air does not flow out, the solenoid valve is in normal condi-
tion.
• Check the resistance between the terminals of the PAIR con-
trol solenoid valve.
PAIR control solenoid valve resistance:
Approx. 22
Ω
at 20 °C (68 °F)
09900-25008: Multi circuit tester set
Tester knob indication: Resistance (
Ω
)
If the resistance is not within the standard range, replace the
PAIR control solenoid valve with a new one.
INSTALLATION
Installation is in the reverse order of removal.
• Connect the PAIR control solenoid valve coupler and PAIR
hoses securely. (
10-18)