ELECTRICAL SYSTEM 9-9
Step 5
1) Measure the generator no-load performance. (
9-11)
Is the generator no-load performance OK?
Step 6
1) Inspect the regulator/rectifier. (
9-11)
Is the regulator/rectifier OK?
Step 7
1) Inspect wirings.
Is the wirings OK?
Battery overcharges
• Faulty regulator/rectifier
• Faulty battery
• Poor contact of generator lead wire coupler
INSPECTION
BATTERY CURRENT LEAKAGE
• Remove the right frame cover. (
8-3)
• Turn the ignition switch OFF.
• Disconnect the battery
-
lead wire.
• Measure the current between
-
battery terminal and the
-
battery lead wire using the multi circuit tester. If the reading
exceeds the specified value, leakage is evident.
Battery current (leak): Under 1 mA
09900-25008: Multi circuit tester set
Tester knob indication: Current (
, 20 mA)
YES
Go to Step 6.
NO
Faulty generator
YES
Go to Step 7.
NO
Faulty regulator/rectifier
YES
Faulty battery
NO
• Short circuit of wire harness
• Poor contact of couplers
* In case of a large current leak, turn the tester to high
range first to avoid tester damage.
* Do not turn the ignition switch ON when measuring
current.