4-72 FI SYSTEM DIAGNOSIS
4) Disconnect the HO2 sensor coupler and measure the resis-
tance between terminals. If the resistance is not specified
value, replace the HO2 sensor with a new one.
HO2 heater resistance: Approx. 8
Ω
at 23 °C (73 °F)
(W – W)
NOTE:
* Temperature of the sensor affects resistance value largely.
* Make sure that the sensor heater is at atmospheric tempera-
ture.
09900-25008: Multi circuit tester set
Tester knob indication: Resistance (
Ω
)
HO2 SENSOR REMOVAL AND
INSTALLATION
• Remove the left frame cover. (
8-3)
• Remove the bracket bolt
1
.
• Disconnect the HO2 sensor coupler
2
.
• Pass the HO2 sensor lead wire
3
between the engine and
frame tube.
• Remove the HO2 sensor
4
.
• Installation is in the reverse order of removal.
• Tighten the HO2 sensor to the specified torque.
HO2 sensor: 25 N·m (2.5 kgf-m, 18.0 lb-ft)
Do not remove the HO2 sensor while it is hot.
* Be careful not to expose it to excessive shock.
* Do not use an impact wrench while removing or
installing the HO2 sensor.
* Be careful not to twist or damage the sensor lead
wires.
Do not apply oil or other materials to the sensor air
hole.