9-18 ELECTRICAL SYSTEM
STARTER RELAY INSPECTION
• Remove the right frame cover. (
8-3)
• Disconnect the battery
-
lead wire from the battery.
• Disconnect the starter relay coupler
1
and remove the starter
relay cover
2
.
• Disconnect the starter motor lead wire
3
and battery lead
wire
4
.
• Remove the starter relay
5
.
• Apply 12 V to
A
and
B
terminals and check for continuity
between the positive and negative terminals using the multi
circuit tester. If the starter relay clicks and continuity is found,
the relay is OK.
09900-25008: Multi circuit tester set
Tester knob indication: Continuity test (
)
Measure the relay coil resistance between the terminals using
the multi circuit tester. If the resistance is not within the specified
value, replace the starter relay with a new one.
Starter relay resistance: 2 – 6
Ω
Tester knob indication: Resistance (
Ω
)
Do not apply battery voltage to the starter relay for
more than five seconds, since the relay coil may over-
heat and get damaged.