9-20 ELECTRICAL SYSTEM
TURN SIGNAL/SIDE-STAND RELAY
The turn signal/side-stand relay is composed of the turn signal
relay, side-stand relay and diode.
• Disconnect the PCV hose
1
.
• Remove the turn signal/side-stand relay
2
.
SIDE-STAND RELAY INSPECTION
First check the insulation between
D
and
E
terminals with the
tester. Then apply 12 V to terminals
D
and
C
(
+
to
D
and
-
to
C
) and check the continuity between
D
and
E
. If there is no
continuity, replace the turn signal/side-stand relay with a new
one.
09900-25008: Multi circuit tester set
Tester knob indication: Continuity test (
)
DIODE INSPECTION
Measure the voltage between the terminals using the multi cir-
cuit tester. Refer to the following table.
09900-25008: Multi circuit tester set
Tester knob indication: Diode test (
)
NOTE:
If the multi circuit tester reads 1.4 V and below when the tester
probes are not connected, replace its battery.
DIODE
SIDE-STAND RELAY
TURN
SIGNAL
RELAY
+
Probe of tester to:
-
Probe of
tester to:
C
,
B
A
C
,
B
1.4 V and more
(Tester’s battery voltage)
A
0.4 – 0.6 V