10-12 SERVICING INFORMATION
WIRING HARNESS, CABLE AND HOSE ROUTING
WIRING HARNESS ROUTING
1
ECM
*3 Pass the wiring harness outside of the air cleaner bracket.
2
Relay (Check or Main)
*4
Set the fuel pump coupler at the right side of IAT sensor.
Do not pinch the fuel pump lead wire coupler between the fuel
tank and frame, when installing the fuel tank.
3
Regulator/Rectifier
4
Taping clamp
5
Wiring harness
*5
Pass the neutral switch lead wire and generator lead wire
inside of the air cleaner bracket.
6
Clutch cable
*1 Cut off the excess end of clamp.
*6
Before clamping the lead wire, draw the protector tube to the
rear turn signal lead wire coupler.
*2
The tip of clamp must face
upward.
*7 Pass every wiring harness inside of the relay.
Clamp
Clamp
Clamp
Handlebar switch (RH)
Handlebar switch (LH)
*1
*3
*1
Wiring harness
Clamp
Rear turn signal (RH)
*1, *6
*4
*5
Clamp
Clamp
Rear turn signal (LH)
Rear combination
Wiring harness
Clamp
Wiring harness
Clutch cable
Guide
Wiring harness
Clutch cable
Clamp
Clamp
Wiring harness
STVA
STP sensor
20 mm
(0.8 in)
Clamp
Wiring harness
Starter motor
*7
Wiring harness
Generator
Neutral switch
Side-stand switch
8 N.m (0.8 kgf-m, 6.0 lbf-ft)
*2
*6
Содержание TU250X
Страница 1: ......
Страница 2: ......
Страница 41: ...PERIODIC MAINTENANCE 2 23...
Страница 213: ...EXHAUST SYSTEM 6 1 6 EXHAUST SYSTEM CONTENTS EXHAUST SYSTEM 6 2 REMOVAL 6 2 INSPECTION 6 4 INSTALLATION 6 4...
Страница 342: ...10 22 SERVICING INFORMATION SIDE STAND INSTALLATION 50 N m 5 0 kgf m 36 0 lbf ft 55 N m 5 5 kgf m 40 0 lbf ft...
Страница 369: ......
Страница 370: ......