ELECTRICAL SYSTEM 9-39
SERVICING
Visually inspect the surface of the battery container. If any signs
of cracking or electrolyte leakage from the sides of the battery
have occurred, replace the battery with a new one. If the battery
terminals are found to be coated with rust or an acidic white
powdery substance, clean the battery terminals with sandpaper.
RECHARGING OPERATION
• Using the multi circuit tester, check the battery voltage. If the
voltage reading is the 12.0 V (DC) and less, recharge the bat-
tery with a battery charger.
A
Charging period
B
Stop charging
Recharging time: 3 A for 1 hour or 0.7 A for 5 to 10 hours
• After recharging, wait for 30 minutes and more and check the
battery voltage with a multi circuit tester.
• If the battery voltage is the 12.5 V and less, recharge the bat-
tery again.
• If battery voltage is still 12.5 V and less, after recharging,
replace the battery with a new one.
• When the motorcycle is not used for a long period, check the
battery every 1 month to prevent the battery discharge.
* When recharging the battery, remove the battery
from the motorcycle.
* Do not remove the caps on the battery top while
recharging.
Be careful not to permit the charging current to
exceed 3 A at any time.
(V)
(at 0 – 40 ˚C)
14
13
12
11
10
100
Battety charged condition
75
50
25
0 (%)