7-10 COOLING AND LUBRICATION SYSTEM
INSPECTION
• Check the ECT sensor by testing it at the bench as shown in
the figure. Connect the ECT sensor
1
to a circuit tester and
place it in the oil
2
contained in a pan, which is placed on a
stove.
• Heat the oil to raise its temperature slowly and read the col-
umn thermometer
3
and the ohmmeter.
• If the ECT sensor ohmic value does not change in the propor-
tion indicated, replace it with a new one.
Temperature sensor specification
Cooling fan operating temperature:
Standard (OFF
ON): Approx. 105 °C (221 °F)
(ON
OFF): Approx. 100 °C (212 °F)
• If the resistance is noted to show infinity or too much different
resistance value, replace the ECT sensor with a new one.
INSTALLATION
• Install the new gasket washer
1
.
• Tighten the ECT sensor
2
to the specified torque.
ECT sensor: 18 N·m (1.8 kgf-m, 13.0 lbf-ft)
• Pour engine coolant. (
2-15)
• Bleed air from the cooling circuit. (
2-16)
Temperature
Standard resistance
20 °C (68 °F)
Approx. 2.45 k
50 °C (122 °F)
Approx. 0.811 k
80 °C (176 °F)
Approx. 0.318 k
110 °C (230 °F)
Approx. 0.142 k
* Take special care when handling the ECT sensor. It
may cause damage if it gets a sharp impact.
* Do not contact the ECT sensor and the column ther-
mometer with a pan.
Take special care when handling the ECT sensor. It
may cause damage if it gets a sharp impact.
Содержание GW250
Страница 1: ...SERVICE MANUAL GW250 9 9 5 0 0 3 2 1 7 0 0 1 E...
Страница 42: ...2 26 PERIODIC MAINTENANCE...
Страница 98: ...3 50 ENGINE TRANSMISSION PARTS LOCATION 1 Countershaft 2 Driveshaft...
Страница 261: ...EXHAUST SYSTEM 6 1 EXHAUST SYSTEM CONTENTS 6 EXHAUST SYSTEM 6 2 REMOVAL 6 2 INSPECTION 6 3 INSTALLATION 6 3...
Страница 478: ...Printed in Japan L3 CHANGZHOU HAOJUE SUZUKI MOTORCYCLE CO LTD...