4-94 FI SYSTEM DIAGNOSIS
• Install the HO2 sensor is in the reverse order of removal.
Pay attention to the following points:
• Apply anti-seize compound to thread part
a
of HO2 sensor.
• Tighten the HO2 sensor
5
to the specified torque.
HO2 sensor: 25 N·m (2.5 kgf-m, 18.0 lbf-ft)
• Clamp the HO2 sensor lead wire. (
10-14)
• Apply thread lock to the reservoir tank mounting bolt
6
and
tighten it to the specified torque.
Reservoir tank mounting bolt:
6 N·m (0.6 kgf-m, 4.5 lbf-ft)
99000-32110: THREAD LOCK CEMENT SUPER “1322”
or equivalent
Do not apply oil or other materials to the sensor air hole.