42
4-4-2. Channel selection mode
·
When power is supplied to the controller, the CH LED (green) of the connected nozzle (high voltage power
supply module) turns on or flashes. A flashing CH LED indicates the selected CH.
The LED for frequency, ION BALANCE and SNSR display the information of the selected CH.
·
The LED for ION/HV, DAC/AC and NDL display all the information of the connected nozzle (high voltage
power supply module).
·
The controller CH1 to CH4 LED’s correspond to CH no. 1 to 4 set for the high voltage power supply modules.
·
The maximum number of nozzles (high voltage power supply modules) for one controller is 4 pcs.
·
Duplication of CH setting will be recognized as an error.
[ Selection of the channel ]
·
The selected CH will flash.
·
Press the ▼ or ▲ button while the CH LED flashes to select
the nozzle (high voltage power supply module) to display or
set.
·
When the number of nozzles is zero, the CH LED does not
change even by pressing the ▼ or ▲ button.
[Change to the next mode]
·
To change to the next mode and store the selected CH setting
press the
S
button once, the
▲
and
S
button simultaneously
for 2 s or longer, or the S button for 3 s or longer.
·
The selected nozzle (high voltage power supply module)
moves on to the ion generation stop mode by pressing ▼ and
▲
button simultaneously for 2 s or longer and stops the ion
generation. To release, press the S button once or turn the
power off and on again. Refer to[ 4-4-8. Ion generation stop
mode].
Example shows CH1 is selected.
Change the CH setting for multiple modules.
(Default CH switch setting is "1".)
CH set switch
High voltage power
supply module
Flash
(green)
Display example of
IZTC41