3-1-6. Routing of cables
·
Do not apply excess stress to the mounting part of the connector.
·
When the cable is bent, maintain the minimum bend radius.
Minimum bending radius: Power supply cable: 40 mm
Separate cable: 40 mm
High voltage cable: 30 mm
※
Separate cable is optional.
1) Power supply cable
·
This cable supplies power to this product and external equipment
used to control this product.
·
When connecting the controller to the power supply cable,
insert it until it makes a click sound.
·
When removing the power supply cable, press the plug claw to
release the lock and pull it out straight. If mounted or removed in
an inappropriate direction, the connector may be damaged and
cause operation failure.
·
Fix the cable around the connecting part so that stress is not applied to the plug.
·
Connect the lead wires according to the wiring diagram. Unused wires should
be cut short, or insulated using insulation tape.
·
To satisfy the current capacity, make sure to wire 2 brown cables in which
a voltage of 24 VDC is supplied and 2 blue cables in which 0V is connected.
2) Separate cable (optional)
·
Cable for connecting the controller and high voltage power supply module and connecting extension modules
separately. This cable is not necessary when the modules are directly connected.
·
Before connecting the cable, mount the spacers (included) in the male side of the D-sub connector plug on
the high voltage power supply module. Refer to 3-1-4. Connect the controller and high voltage power supply
module.
·
It is not necessary to mount spacers to the controller D-sub connector and the D-sub connector (socket) of
the high voltage power supply module because spacers are already mounted to them.
·
When the separate cable is mounted or removed, pinch the connector with fingers and insert or take out the
plug vertically. If mounted or removed in an inappropriate direction, the connector may be damaged and
cause operation failure.
·
After connecting the separate cable, fix screws of the connector. Mount the dust cover to any D-sub connector
which is not used.
Spacer tightening torque: 0.4 to 0.6 Nm
Separate cable tightening torque: 0.25 to 0.35 Nm
Power supply cable
Controller
Claw of the plug
IZTC41
Controller
IZT40-CF
□
Separate cable
IZTP43
High voltage power supply module
Spacer(Included)
D-sub connector
Socket
D-sub connector