39
4-1-2. High voltage power supply module
1)
IZTP43
Table5. Name of parts
4-2.
Operation modes
·
The product has 3 operation modes. AC mode and DC mode.
Ionizer operation modes
AC mode
IZT43
DC mode (Either positive ions or negative ions are continuously discharged during
operation)
1) AC mode
·
Ions of different polarity are generated alternately according
to the frequency set by the frequency set mode.
·
If the offset voltage (ion balance) is displaced by the installation
environment, adjust the offset voltage.
·
Refer to [4-4-3. Frequency set mode] for frequency setting and
[4-4-4. Offset voltage adjustment mode] for the adjustment of
the offset voltage (ion balance).
1
2
4
3
No.
Name
Panel
indication
Type
Description
1
CH number set switch
CH
Rotary switch
High voltage power supply module CH number setting.
2
High voltage cable connector
-
Connector
Connect with the high voltage cable of the bar IZTN43
3
High voltage power supply
module connector
-
D-sub connector
(socket)
Connect high voltage power supply module or separate cable.
4
Controller/ high voltage
power supply module connector
-
D-sub connector
(plug)
Connect the controller, high voltage power supply module or separate cable.
Ion generation image in AC mode
Содержание IZT43 Series
Страница 1: ...Document No IZ OMX0087 PRODUCT NAME Ionizer MODEL Series IZT43 series...
Страница 59: ...Controller IZTC41 IZTC41 P When DIN rail mounting bracket IZT40 B1 is used When power supply cable is inserted...
Страница 60: ...High voltage power supply module IZTP43 When DIN rail mounting bracket IZT40 B2 is used...