4-4-8. Ion generation stop mode
·
In addition to the external input signal, the product will stop ion generation temporarily by pressing a button.
·
When the ion generation is stopped by the controller button, the external input signals are disabled. To release
the mode, press the
S
button once to return to the previous setting mode. After the release of the button, the
external input signal becomes effective.
·
When the ion generation stop is disabled, ions will continue to be generated. Be careful when handling the
high voltage power supply module and nozzle.
·
Although the ion generation stop mode can be released by turning the power supply off and on again, the
changes set in the previous mode will not be stored. It is necessary to change the setting again.
[Ion generating stop setting]
·
In Channel selection mode, frequency set mode,
offset voltage adjustment mode, balance control
selection mode or maintenance detection level
selection mode, ion generation is stopped by pressing
he
▼ and ▲
button simultaneously for 2 s or longer.
·
At that time, "
5p
" is displayed in the frequency
display and the ION/HV LED of the selected CH is
turned off.
[Ion generation stop release]
·
To release the mode, press the
S button once to
return to the previous setting mode.
·
Although the ion generation stop mode can be
released by turning the power supply off and on again,
the changes set in the previous mode will not be
stored. It is necessary to change the setting again.
※
When the ion discharge stop signal is ON, the
mode will not move on to ion generation stop mode.
Display example of
IZTC41
Flash
(green)
OFF