41
4-4. Controller setting
4-4-1. Operation overview
1) Setting IZT43
(Default condition)
Frequency setting
: 30Hz
Key lock
: OFF
Built-in sensor
: ON
Maintenance detection level
: MIDDLE
Note 31) In Channel selection mode, frequency set mode, offset voltage adjustment mode, balance control
selection mode or maintenance detection level selection mode, the selected nozzle (high voltage power
supply module) moves on to the ion generation stop mode by pressing
▼ and ▲
button simultaneously for 2 s
or longer and stops the ion generation (Operation is not possible while the key lock is ON or externally input
signal is ON). To release, press the S button once or turn the power off and on again. Refer to [ 4-4-8. ion
generation stop mode] for further details.
[Channel selection mode]
Select the CH number for setting and display. When multiple nozzles (high voltage power supply modules)
are connected, switch the CH for setting and display. Refer to 4-4-2. Channel selection mode for details.
Note 31)
[Frequency set
mode]
Set the ion generation
frequency of the nozzle
selected by "Channel
selection mode”.
Refer to 4-4-3. Frequency
set mode for details.
Note 31)
[ Key-lock setting
mode]
Perform a key-lock setting.
Refer to 4-4-7. Key-lock
set mode for details.
[ Balance control
selection mode ]
Select ON/ OFF of the
balance control by the
sensor built in the high
voltage power supply module
selected in "Channel
selection mode"
Refer to 4-4-5. Balance
control selection mode for
details. Note 31)
[Offset voltage
adjustment mode]
Adjust the offset voltage
of the nozzle selected
by ”CH selection mode".
Refer to "4-4-4.
Adjustment of Offset
Voltage" for details.
Note 31)
[ Emitter contamination
detection level
selection mode]
Set the contamination
detection level of the high
voltage power supply
module emitter selected by
"Channel selection mode".
Refer to 4-4-6. Emitter
contamination detection level
selection mode for details.
Note 31)
[Channel selection mode]
Press S button
once
Press S button
once
Press S button
once
Press S button
once
Press S button for
3 sec. or longer
Press the
▲
button and
S button at the same time
for
2 seconds or longer.
Power is supplied.
Press S button
once
Press S button
once