5
1) This product is intended for use in general factory automation equipment.
·
If considering using the product for other applications (especially those indicated in (4) on page 3), please
consult SMC beforehand.
2) Use within the specified voltage and temperature range.
·
Operation with a voltage other than that specified can cause malfunction, damage to the product, electric
shock or fire.
3) Use clean compressed air as fluid. (Air quality Class 2.6.3 specified in ISO 8573-1: 2012 is
recommended.)
·
Never use flammable gas or an explosive gas as a fluid and never use this product in the presence of such
gases.
·
Please contact us when fluids other than compressed air used.
4) This product is not designed to be explosion proof.
·
Never use in an atmosphere of potentially explosive dust, flammable gas or explosive gas. Fire or an
explosion can result.
1) Clean room specification is not available.
·
When using in a clean room environment, confirm the required cleanliness before use.
·
Fine particles are generated due to wear of emitters and motor sliding during operation.
1) Reserve an enough space for maintenance, piping and wiring.
·
Please take into consideration that the one-touch fittings for supplying air, need enough space for the air
tubing to be easily attached/detached.
·
To avoid unreasonable stress applied to the connector and one-touch fitting mounting parts, bending of the
cable or air tubing should be more than the minimum bending radius.
·
If the cable is bent in an acute angle or load is applied to the cable repeatedly, it may cause malfunction, wire
damage or fire.
Minimum bending radius: Power supply cable: 40 mm
Separate cable (optional): 40mm
High voltage cable: 30mm
NOTE: This is an allowable bend radius at 20
o
C. Bend radius should be larger at lower than 20
o
C.
Regarding the minimum bending radius of the air tubing, refer to the operation manual or catalog
for tubing.
2) Wiring high voltage cable
·
Use specified cable holder (IZT40-E1 or IZT40-E2) for installing high voltage cables.
·
Follow the items below when installing high voltage cables. If items below are not followed, insulation
performance of high voltage cable decreases, causing the failure of this product, leading to electrical shock
or fire.
a. Do not cut the cable.
b. Keep the minimum bend radius of the cable.
c. Do not tighten the cable too much by tying band. Do not deform the cable by placing object on the cable.
d. Avoid the factor of cable runaway such as cable duct.
e. Do not twist or damage to the cable. If the cable is damaged, it should be replaced.
3) Fix the high voltage cable connector using 2 screws included in accessory.
·
Fix the connector using 2 cross recessed round head screws (M4 x10L) referring to Table 1. Reference of
tightening torque.
Warning
Caution