46
4-4-6.
Maintenance detection level selection mode
·
If this product is used for an extended period of time, contamination such as dust will stick to the emitters,
reducing the static neutralization performance.
·
It is recommended to clean the emitters when the maintenance alarm is generated.
·
The cleaning frequency varies depending on the environment where this product is installed.
·
This product has a function which monitors the emitter contamination all the time. When the emitter
contamination is detected, it is indicated by the maintenance signal and LED.
·
In maintenance detection level selection mode, the detection level of the emitter contamination can be set.
[Maintenance detection level selection method]
·
In CH selection mode, press the S and
▲
buttons simultaneously for 2 s or
longer to move to balance control selection mode.
·
By pressing the S button once, “
Xi
” or “
Mi
” or “
Lo
” or “
oF
” will flash in the
frequency display. The maintenance detection level can now be selected.
·
It can be set by pressing the
▼
or
▲
button.
Lo
(Low)
・・・・・
Static neutralization time is slower than the initial state
Mi
(Middle)
・・・
Before the static neutralization time becomes slow
Xi
(High)
・・・・・
No influence to the static neutralization time
oF
(OFF)
・・・・・・
Maintenance detection is OFF
[Change to the next mode]
·
Press the S button once to change to the next mode and store the
maintenance detection level selection setting.
·
When power is supplied, the saved setting will be displayed.
·
The selected nozzle (high voltage power supply module) moves on to the ion
generation stop mode by pressing ▼ and
▲
button simultaneously for 2 s or
longer and stops ion generation. To release, press the S button once or turn
the power off and on again. Refer to [ 4-4-8. ion generation stop mode].
※
Caution
If the mode is changed to ion generation stop mode during maintenance
detection level selection or the power supply is turned off, the change to the
setting will not be stored. Change the setting again.
Default maintenance detection level setting is "Middle".
Change the setting to change the maintenance detection level.
Example shows the emitter
contamination detection
level of CH1.
Flash
(green)
Display example of
IZTC41
Low
Middle
High
OFF
Содержание IZT43 Series
Страница 1: ...Document No IZ OMX0087 PRODUCT NAME Ionizer MODEL Series IZT43 series...
Страница 59: ...Controller IZTC41 IZTC41 P When DIN rail mounting bracket IZT40 B1 is used When power supply cable is inserted...
Страница 60: ...High voltage power supply module IZTP43 When DIN rail mounting bracket IZT40 B2 is used...