4-4-5. Balance control selection mode
·
IZT43 have a built in sensor to balance the ions generated.
·
Balance control selection mode turns the balance control by the built-in sensor on and off.
[Selection of balance control]
·
Select the CH to be set in CH selection mode and press the S button
and
▲
button simultaneously for 2 s or longer. The frequency
display indicates "
5n
" flashing, and the switching of ON and OFF
of balance control is now possible.
·
The Sensor display (SNSR) LED (green) alternates ON and OFF
each time the
▼
or
▲
button is pressed.
Balance control ON: Sensor display (SNSR) LED is ON
Balance control OFF: Sensor display (SNSR) LED is OFF
[Change to the next mode]
·
Press the S button once to change to the next mode and store the
balance control selection setting.
·
When power is supplied the saved setting will be displayed.
·
The selected nozzle (high voltage power supply module) moves on
to the ion generation stop mode by pressing ▼ and
▲
button
simultaneously for 2 s or longer and stops ion generation. To
release, press the S button once or turn the power off and on again.
Refer to [ 4-4-8. ion generation stop mode].
※
Caution
If the mode is changed to ion generation stop mode during balance
control selection or if the power supply is turned off, the change to the
setting will not be stored. Change the setting again.
Default balance control setting is ON.
Example shows the ON status of CH1
balance control.
Flash
(green)
ON
(green)
or
OFF
Display example of
IZTC41