21
3)
Installation of the nozzle
·
Fix the bracket to the specified position using M3 screws.
·
Refer to "6. Dimensions" section for details.
(The screws should be prepared by the user. Fixed part thickness 1mm, Recommended mounting screw is
M3x5)
4)
Mounting angle adjustment
·
Adjust the mounting angle of the nozzle for effective neutralization, and fix the product.
Tightening torque: 0.61 to 0.65 Nm
3-1-4. Connecting the controller and high voltage power supply module
·
Remove the protection film on the controller before use.
·
The product is used by connecting the controller and high voltage power supply module. They can be
connected either directly or separately. For separate connection, an optional separate cable is required.
·
Mount a dust cover on the D-sub connector when not using the directly mounted high voltage power supply
module.
1)Direct connection
·
Fix the controller and high voltage power supply module using cross recessed round head screw (M4x30).
Tightening Torque: 0.22 to 0.24Nm
Dust cover
(Included)
M4 screw
(Included)
IZTC41
Controller
IZTP43
High voltage power supply module
M3 screw
M3 screw
M3screw
30°
Содержание IZT43 Series
Страница 1: ...Document No IZ OMX0087 PRODUCT NAME Ionizer MODEL Series IZT43 series...
Страница 59: ...Controller IZTC41 IZTC41 P When DIN rail mounting bracket IZT40 B1 is used When power supply cable is inserted...
Страница 60: ...High voltage power supply module IZTP43 When DIN rail mounting bracket IZT40 B2 is used...