1) Before wiring, ensure that the power supply capacity meets the specification and that the voltage is
within the specification.
Product damage or malfunction can result.
2) To maintain product performance, the power supply should be UL Class 2 certified by National Electric
Code (NEC) or evaluated as a limited power source according to UL60950.
3) To maintain the product performance, ground the product with an earth ground cable with a resistance
of 100 Ω or less. If the product is not grounded, it is not possible to secure the performance and may
lead to product failure or malfunction.
4) Wiring (including insertion and removal of the power supply connector) should never be carried out
with the power supply ON. Otherwise, an electrical shock or accident may occur.
5) Use specified cable for connecting the ionizer controller, high voltage power supply module and nozzle.
Do not disassemble or retrofit them.
Disassembling or modifying the product may cause product,
electric shock or fire. The product will not be guaranteed if it is disassembled and/or modified.
6) Ensure the safety of wiring and surrounding conditions before supplying power.
7) Do not connect or disconnect the connectors (including power source) while the power is supplied.
Failure to follow this procedure may cause product malfunction.
8) If the power and high voltage cables are routed together, the product may malfunction due to noise.
Route the Ionizer wires separately.
9) Confirm that the wiring is correct before operation. Incorrect wiring will lead to product damage or
malfunction.
10) Flush the piping before connecting. Before piping this product, exercise caution to prevent particles,
water drops, or oil contents from entering the piping.
1) Operate the product in the specified fluid temperature range and ambient temperature range.
·
Operating fluid temp. and ambient temp. range: 0 to 40
o
C.
·
Do not use the product in locations where the temperature may change suddenly even if the ambient
temperature range is within the specified limits, resulting in condensation.
2) Do not use this product in an enclosed space.
·
This product utilizes the corona discharge phenomenon. Do not use the product in an enclosed space as
ozone and nitrogen oxides exist, even though in marginal quantities.
3) Environments to avoid
·
Never use or store under the following conditions. These may cause an electric shock, fire, etc.
a. Use in the environment which ambient temperature is out of the product specification.
b. Use in the environment which ambient humidity is out of the product specification.
c. Environment where abrupt temperature changes may cause condensation.
d. Environment where corrosive gas, flammable gas or other volatile flammable substances are stored.
e. Environment where the product may be exposed to conductive powder such as iron powder or dust, oil
mist, salt, organic solvent, machining chips, particles or cutting oil (including water and any liquids), etc.
f. Paths of direct air flow, such as air conditioners.
g. Enclosed or poorly ventilated environment
h. Locations which are exposed to direct sunlight or heat radiation.
i. Areas where strong electromagnetic noise is generated, such as strong electrical and magnetic fields or
supply voltage spikes.
j.
Environment where static electricity is generated to the product.
k. Locations where strong high frequency is generated.
l. Locations which are subject to potential lightning strikes.
m. In an area where the product may receive direct impact or vibration.
n. Areas where the product may be subjected to forces or weight that could cause physical deformation.
4) Do not use air containing mist and/or dust.
·
Air containing mist and/or dust may cause performance deterioration, and reduce the maintenance cycle.
·
Install a dryer (IDF series), air filter (AF/AFF series), and/or mist separator (AFM/AM series) to obtain clean
compressed air (air quality of Class 2.4.3, 2.5.3, 2.6.3 or higher according to ISO 8573-1: 2010 (JIS B8392-
1:2012) is recommended for operation.
Wiring and Piping
Wiring and Piping
Warning
Operating / Storage Environment
Warning
Содержание IZT43 Series
Страница 1: ...Document No IZ OMX0087 PRODUCT NAME Ionizer MODEL Series IZT43 series...
Страница 59: ...Controller IZTC41 IZTC41 P When DIN rail mounting bracket IZT40 B1 is used When power supply cable is inserted...
Страница 60: ...High voltage power supply module IZTP43 When DIN rail mounting bracket IZT40 B2 is used...