10
3) Do not disassemble or modify the product.
·
Disassembling or modifying the product may cause product, electric shock or fire. The product will not be
guaranteed if it is disassembled and/or modified.
4) Do not operate the product with wet hands.
·
Never operate the product with wet hands. It may cause electric shock or other accidents.
5) Be sure to remove power supply and air supply to the controller, high voltage power supply module
and nozzle before replacing the high voltage cable.
1) Do not apply excessive external force or shock (100m/s
2
or more) to the product
·
Even if the there are no problems with the appearance of the controller, high voltage power supply module or
nozzle, the damage of the internal components may cause malfunction.
2) Power cable must be connected and disconnected by hand.
·
Open and close too much may damage the drain cock.
·
Hold the connector by hand and straightly pull it out.
·
If the connector has lock mechanism, release the lock and then pull out the connector.
3) If smoking, fire or smell occurs in the product, immediately shut off the power supply.
4) Do not touch the A part and the F part of the high voltage cable by hand. Be careful so that moisture
or foreign matter does not adhere to the connector.
·
Do not touch the A part and the F part of the high voltage connector by hand while handling.
·
Keep the high voltage connector free from contamination. Adhesion of oil or foreign matter on the A part
and the F part may cause high voltage electric leakage.
·
If moisture, oil, or foreign matter adheres to the A part, clean it with ethanol.
Handling
Caution
(1) Insert the cartridge.
(2) Rotate the emitter cartridge
for in the clockwise direction.
Mounting of the emitter
cartridge
High voltage connector
(Back)
A
A
(3) Slide to lock.
F
High voltage plug
Содержание IZT43 Series
Страница 1: ...Document No IZ OMX0087 PRODUCT NAME Ionizer MODEL Series IZT43 series...
Страница 59: ...Controller IZTC41 IZTC41 P When DIN rail mounting bracket IZT40 B1 is used When power supply cable is inserted...
Страница 60: ...High voltage power supply module IZTP43 When DIN rail mounting bracket IZT40 B2 is used...