Controller, high voltage power supply module, nozzle and AC adapter are not resistant to lightening
surge.
6. Effects on implantable medical devices.
·
The electromagnetic waves emitted from this product may interfere with implantable medical devices such
as cardiac pacemakers and cardioverter defibrillators, resulting in the malfunction of the medical device or
other adverse effects.
·
Please use extreme caution when operating equipment which may have an adverse effect on your
implantable medical device. Be sure to thoroughly read the precautions stated in the catalog, operation
manual, etc., of your implantable medical device, or contact the manufacturer directly for further details on
what types of equipment need to be avoided.
1) Perform maintenance regularly and clean the emitters.
·
Check regularly that the product is not operating with
undetected failures.
·
The maintenance must be carried out by an operator
who has sufficient knowledge and experience.
·
If the product is used for an extended period with dust
present on the emitters, the product performance will be
reduced.
·
Maintenance detection function is installed to
IZT43. When the emitter contamination is
detected, clean the emitter.
·
In cases where the maintenance detection function is not used on the IZT43 is used, perform neutralizing
performance test and set maintenance cycle for periodic cleaning.
·
Emitter contamination level is different depending on the installation environment and supply pressure.
Refer to section "9. Maintenance" for details.
·
If the performance is not recovered after cleaning, it is possible that emitters are worn. Replace the emitter
cartridge.
2) Be sure to remove power supply and air supply to the controller, high voltage power supply module
and nozzle before cleaning the emitter or replacing the emitter cartridge.
·
Never touch the emitter with the power supplied to the controller, high voltage power supply module or nozzle.
Electric shock may cause injury.
·
If the emitter cartridge is removed while air is supplied, the emitter cartridge jumps out by compressed air.
Replace the emitter cartridge after discharging the supply air.
·
If emitter cartridges are not securely mounted to the body, they may eject or release when air is supplied to
the product.
·
Securely mount or remove the emitter cartridges referencing the instructions shown below.
·
Securely mount or remove the emitter cartridges with hands and do not use tools.
(Tightening torque: 0.1 to 0.2 Nm)
Maintenance / Check
Warning
(2)Rotate the cartridge in the
counter-clockwise direction.
(3) Pull to remove.
Removal of the emitter
cartridge
・
This product contains a high voltage
generation circuit. When performing
maintenance inspection, be sure to
confirm that the power supply to the
ionizer is turned off.
・
Never disassemble or modify the
product, as this can cause loss of
product functionality, and there is also a
risk of electric shock and earth leakage.
High voltage caution
(1) Slide to unlock