27
d. Install to DIN rail
·
Mount them on to the DIN rail and connect the additional high voltage power supply module D-sub
connector.
e.
Mount the fixing bracket
·
Mount the fixing brackets (included as an accessory) in location D.
f. Fix to DIN rail
·
After installing to the DIN rail, fix the controller and high voltage
power supply module using set screws.
Tightening Torque: 1.30 to 1.50 Nm
g.
High voltage power supply module CH number setting
·
Set the CH number setting switch for all connected high voltage power
supply modules.
·
Set the CH number so that it does not duplicate the set number of
other channels.
(
Refer to 4-3. High voltage power supply module CH number setting.
)
If duplicated, it will be verified as an error.
(
Refer to 4-5. Alarms for details.
)
D : Fixing bracket
Change the CH setting for
multiple connection.
(
Default CH switch setting is "1".
)
CH set switch
High voltage power supply module
High voltage power supply
module to be added
D-sub connector
High voltage power supply module
to be added
Holding screw