32
NPN type
When an ionizer (IZT43) is used in DC mode, make sure to ground the F.G. cable (green) and DC(-) cable
(blue) of the input power supply
with a resistance of 100 ohms or less.
Without grounding the DC(-) cable,
this product and/or power supply may be damaged.
Controller (IZTC41)
In
te
rn
a
l ci
rcu
it
PLC
OUTPUT
INPUT
OUTPUT
+24V
+24V
DC/DC
0V
0V
+24V
+24V
+24V
+24V
+24V
or
or
or
or
Be sure to ground.
Be sure to ground.
+
24 VDC
-
F.G.
Power supply
24VDC
Shield
Green F.G.
Brown (2cables)
DC(
+
)
Pink Ion generation stop
CH1
White Maintenance detection
signal
Black Error signal
INPUT
Blue (2 cables) DC(
-
)
Gray Ion generation stop
CH2
Yellow Ion generation stop
CH3
Purple Ion generation stop
CH4
Power
supply
Power
supply