6
4) Mount to the flat surface and do not apply impact load or excessive external force.
·
Mounting on an uneven surface will apply excessive force to the housing and bracket, which may lead to
damage or failure.
·
Do not drop or apply excessive shock. Otherwise, damage or an accident may occur.
5) Be sure to fix the High voltage cable plug with the cable clip and the cross recessed round head
screw (M3 x5L).
6) Avoid using in a place where noise (electromagnetic wave and surge) is generated.
·
If the product is used in an environment where noise is generated, it may lead to malfunction or deterioration
or damage of the internal elements.
·
When the presence of noise is suspected, take preventive measures against noise and avoid the crossing
wires such as power line and high voltage line.
7) Tighten the screws to the specified torque.
·
If the screws are tightened in excess of the specified torque range, it may damage the mounting screws or
mounted areas.
·
If the tightening torque is insufficient, the mounting screws and brackets may become loose.
8) Do not directly touch the emitters.
·
Do not directly touch the emitter with your finger. If the needle sticks to your finger, or electrical shock makes
an instantaneous rapid body motion to escape from the shock, causing injury.
·
If emitter or cartridge is damaged by tools, etc., it may interfere with the specified function and performance,
and may also cause operation failure and accident.
0
9) Do not affix any tape or labels to the controller, high voltage power supply module or nozzle.
·
If the tape or label contains any conductive adhesive or reflective paint, a dielectric phenomenon may occur
due to ions arising from such substances, resulting in electrostatic charging or electric leakage, causing
malfunction, breakage, electric shock or fire.
The emitter carries high voltage. If foreign matter is
inserted or human body touches the emitter,
electrical shock or instantaneous reaction of body
to escape from the shock, causing injury.
High voltage caution
Parts
Product No.
Connection
Screw (Accessory)
Tightening torque
Note
L-type bracket
IZT43-BL1
Nozzle
M3x4L
0.6 to 0.65Nm
Installation of bracket for nozzle
Nozzle
M3x4L
0.61 to 0.65Nm
Installation of bracket for nozzle
Bracket
(For angle adjustment)
M3x4L
2pcs.
0.61to 0.65Nm
Mounting angle adjustment
Nozzle
M3x5L
0.10 to 0.15Nm
Installation of bracket for high
voltage cable plug
Controller
2pcs.
0.25 to 0.35Nm
High voltage power
supply module
2pcs.
0.25 to 0.35Nm
D-sub connector(plug)
2pcs.
0.40 to 0.60Nm
Controller
M4x6L
2pcs.
1.30 to 1.50Nm
High voltage power
supply module
M4x6L
IZT40-B2
:
4pcs.
IZT42-B3
:
8pcs.
1.30 to 1.50Nm
DIN rail mounting bracket
Spacer for separate cable
Separate cable
Controller
Table 1. Reference of tightening torque
IZTC41
High voltage power
supply module
M4x30L
2pcs.
0.22 to 0.24Nm
Direct connection
Installation of bracket for high
voltage cable connector
Nozzle
Angle adjustment
bracket
IZT43-BL2
Nozzle (High voltage
cable)
IZTN43-
□□□□
-
□
High voltage power
supply module
M4x10L
2pcs.
0.49 to 0.53Nm
IZT40-CF
□
Separate connection
IZT40-B
□
DIN rail mounting bracket
DIN rail
M4x6L
2pcs.
1.30 to 1.50Nm
Install to DIN rail