6) Fan motor failure
·
When fan motor operation non-conformance occurs during the operation of this product, the abnormal signal
is OFF (ON when normal.), and the ION/HV LED for the CH with abnormality is flashing (red) and the error
code "
E5
" is flashing in the frequency display.
·
When the problem occurs, only the nozzle with a problem (high voltage power supply module) will stop ion
generation.
·
To prevent noise, perform the following actions and take countermeasures.
Ⅰ
. If the source of noise is nearby, move this product away from the source.
Ⅱ
. Route the power line and this product cables separately.
Ⅲ
. If noise may enter the product from the power supply, install a noise filter to this product power supply.
·
To resolve the error, input the ion discharge stop signal or supply power again after remedying the cause of
the error.
7) Incompatible module
·
When the high voltage power supply module IZTP40 is connected to the controller IZTC41, the abnormal
signal is OFF (ON when normal.), and the ION/HV LED of CH with abnormality is flashing (red) and the
error code "
E6
" is flashing in the frequency display.
·
To release the abnormality, connect the correct high voltage power supply module corresponding to the
controller and turn on the power supply again.
8) Duplication of CH number
·
When multiple nozzles (high voltage power supply modules) are connected to the controller and the settings
of the CH switch on the high voltage power supply module are duplicated, the abnormal signal is OFF (ON
when normal.), and the ION/HV LED for the CH of the nozzles (high voltage power supply module) which
are duplicated are flashing (red) and the error code "
E7
" is flashing in the frequency display.
·
The abnormality is automatically released when the setting of the CH switch on the high voltage power
supply module is not duplicated.
9) Output over current
·
When current exceeding the specification value is applied to the maintenance output or abnormal output,
the output is shut off to protect the output circuit, and the LEDs for all ION/HV connected to the nozzle (high
voltage power supply module) flash (green) and the error code "
E8
" or "
E9
" is flashing in the frequency
display.
·
E8
indicates excess current for the abnormal signal.
E9
indicates excess current for the maintenance
signal.
·
This product operates even when excessive current is generated in the output circuit.
·
To resolve the error, reset the product automatically by reducing the current to the output circuit down to
100 mA or less.
10) Maintenance
·
The maintenance signal is ON when contamination, wear or damage to the emitters is detected. The NDL
LED (green) for the nozzle with the problem (high voltage power supply module) is ON to indicate that
cleaning or replacement of the emitters needs to be performed.
·
This product operates even when the maintenance warning is generated.
·
When emitters are contaminated, the error can be solved by cleaning them. However, when they are worn
out or damaged, it is necessary to replace the emitter cartridge with a new one.
·
To resolve the error, input the ion discharge stop signal or supply power again after remedying the cause of
the error.
11) High voltage power supply module disconnected
·
When the controller and high voltage power supply module are not connected, the abnormal signal is OFF
(ON when normal.), and error code "
--
" is flashing in the frequency display.
·
To release the abnormality, connect the high voltage power supply module to the controller and turn on the
power supply.