background image

DESCO WEST 

- 3651 Walnut Avenue, Chino, CA 91710 • (909) 627-8178

DESCO EAST 

- One Colgate Way, Canton, MA 02021-1407 • (781) 821-8370 • Website: 

Desco.com

TB-8003

 Page 1 of 5

© 2021 DESCO INDUSTRIES INC

Employee Owned

Benchtop AC Ionizer

Installation, Operation, and Maintenance

Description

The Trustat

®

 

19550

 Benchtop AC Ionizer is used for 

neutralizing electrostatic charges on insulators and 

ungrounded conductors. Its discharge times 

(< 1 second at 12") and ±10 Volt offset voltage meet 

the required limits of ANSI/ESD S20.20 and ESD 

TR53. The Trustat

®

 Benchtop AC Ionizer generates 

AC high voltage to produce an airflow rich in positive 

and negative ions. The fan speed is controlled by a 

two-state rocker switch for low (52 CFM) and high (76 

CFM) airflow. The low wattage heating element can be 

enabled to improve operator comfort. The emitters can 

be quickly and regularly cleaned by fully rotating and 

releasing the knob located over the center of the fan. 

The Trustat

®

 Benchtop AC Ionizer features a powder 

coated steel enclosure and stand.

November 2021

Ionizers are useful in preventing electrostatic charge 

generation, electrostatic discharge, electrostatic 

attraction, as well as preventing equipment latch-up.  

Per ANSI/ESD S20.20 section 6.2.3.1. Protected 

Areas Requirement states: “Ionization or other charge 

mitigating techniques shall be used at the workstation 

to neutralize electrostatic fields on all process essential 

insulators if the electrostatic field is considered 

a threat.”  “Air ionization can neutralize the static 

charge on insulated and isolated objects by producing 

separate charges in the molecules of the gases of 

the surrounding air.  When an electrostatic charge is 

present on objects in the work environment, it will be 

neutralized by attracting opposite polarity charges from 

the ionized air.  Note that ionization systems should 

not be used as a primary means of charge control on 

conductors or people.” (Reference: EN 61340-5-2:1 

clause 5.2.9)
“The primary method of static charge control is direct 

connection to ground for conductors, static dissipative 

materials, and personnel. A complete static control 

program must also deal with isolated conductors 

that cannot be grounded, insulating materials (e.g., 

most common plastics), and moving personnel who 

cannot use wrist or heel straps or ESD control flooring 

and footwear. Air ionization is not a replacement for 

grounding methods. It is one component of a complete 

static control program. Ionizers are used when it is not 

possible to properly ground everything and as backup 

to other static control methods.  In clean rooms, air 

ionization may be one of the few methods of static 

control available.” (ESD Handbook ESD TR20.20 

Ionization, section 5.3.6.1 Introduction and Purpose / 

General Information)

Packaging

1 Trustat

®

 Benchtop AC Ionizer

1  Snap-on Filter Retainer

1  Air Filter

1  Power Cord with North America Plug, 6 ft.

1  Certificate of Calibration

User Guide

TB-8003

Figure 1. Trustat® 19550 Benchtop AC Ionizer

Содержание Trustat 19550

Страница 1: ...elds on all process essential insulators if the electrostatic field is considered a threat Air ionization can neutralize the static charge on insulated and isolated objects by producing separate charges in the molecules of the gases of the surrounding air When an electrostatic charge is present on objects in the work environment it will be neutralized by attracting opposite polarity charges from t...

Страница 2: ...the filter onto the air intake grill at the back of the ionizer G Power Inlet Connect the power cord here H Fuseholder Stores the 5 A slow blow fuse for powering the ionizer I Ground Terminal For best performance the blower chassis ground terminal and all worksurfaces in proximity to the target i e wokbench ESD mat should always be wired to a reliably earthed electrical point Installation Place th...

Страница 3: ...xtensive maintenance and cleaning beyond that described above NOTE The AC power cord MUST be disconnected before the unit can be disassembled for maintenance First turn the unit OFF and unplug the power cord Unthread and remove 3 Phillips head screws on each side and 2 in rear 8 total The bottom base chassis plate and ionization circuit subassembly can next be separated from the top cover chassis ...

Страница 4: ...e fan speed set to high All measurements are in seconds NOTE Discharge times in seconds are representative only and are not a guarantee Discharge times are actual measurements recorded in a factory ambient environment TP1 60 60 12 12 12 12 12 TP4 60 60 TP7 17 9 23 7 TP10 15 5 16 5 TP2 1 4 1 9 TP5 2 6 3 1 TP8 3 8 4 7 TP11 5 5 6 8 TP3 60 60 TP6 60 60 TP9 60 60 TP12 60 60 Trustat AC Benchtop Ionizer ...

Страница 5: ...ring IEC 320 C14 AC inlet with fuseholder Input Cord NEMA 5 15P to IEC 320 C13 6 ft Input Fuse 5A slow blow Chassis Steel enclosure powder coated epoxy polyester paint finish Air Filter Optional Open cell polyurethan foam 30 pores per in Ozone 0 01 ppm fan LOW 6 in Audible Noise 54 dBA SPL fan LOW 1 ft 61 dBA SPL fan HIGH 1 ft Weight 7 1 lbs 3 2 kg Dimensions with stand knobs 9 x 7 5 x 5 25 229 mm...

Отзывы: