DESCO WEST 

- 3651 Walnut Avenue, Chino, CA 91710 • (909) 627-8178

DESCO EAST 

- One Colgate Way, Canton, MA 02021-1407 • (781) 821-8370 • Website: 

Desco.com

TB-8003

 Page 2 of 5

© 2021 DESCO INDUSTRIES INC

Employee Owned

Features and Components

A. Emitter Point Cleaner Knob:

 Remove the cap 

to expose the balance offset voltage adjustment 

potentiometer. Turn the potentiometer clockwise 

for positive adjustment. Turn the potentiometer 

counter-clockwise for negative adjustment.

B. Tilt Lock Knob:

 Loosen and tighten the two knobs to 

tilt the ionizer and alter its direction of airflow. 

C. Heater Switch:

 Toggle the switch up to turn the 

heater ON. Toggle the switch down to turn the heater 

OFF.

D. Power Switch:

 Toggle the switch up to turn the 

ionizer ON. Toggle the switch down to turn the ionizer 

OFF.

E. Fan Speed Switch:

 Toggle the switch up to set the 

fan speed to HIGH. Toggle the switch down to set the 

fan speed to LOW.

F. Snap-on Filter Retainer:

 Use the snap-on retainer 

to install the filter onto the air-intake grill at the back of 

the ionizer. 

G. Power Inlet:

 Connect the power cord here.

H. Fuseholder:

 Stores the 5 A slow-blow fuse for 

powering the ionizer. 

I.  Ground Terminal:

 For best performance, the 

blower chassis-ground terminal and all worksurfaces in 

proximity to the target (i.e. wokbench, ESD mat) should 

always be wired to a reliably earthed electrical point.

Installation

Place the unit at a desired location where the airflow 

will not be restricted. Use the tilt lock knobs to aim the 

ionizer at the area to be neutralized. Ensure that the 

power switch is set to OFF. Connect the ionizer’s power 

cord into an appropriate AC power source.

Operation

 

1.  Position the ionizer so that maximum airflow is 

directed towards the items or area to be neutralized. 

2.  Turn the unit ON. The power LED will illuminate and 

remain solid. 

3.  Set the fan speed switch to the desired setting. 

Higher airflow will result in faster discharge times. 

4.  Use the heater switch as desired to enable the 

heater for operator comfort.

Figure 3. Using the Trustat® Benchtop Ionizer at a 

workstation

Figure 2. Trustat® Benchtop Ionizer features and 

components

A

C

D

E

F

G
H

B

I

Содержание Trustat 19550

Страница 1: ...elds on all process essential insulators if the electrostatic field is considered a threat Air ionization can neutralize the static charge on insulated and isolated objects by producing separate charges in the molecules of the gases of the surrounding air When an electrostatic charge is present on objects in the work environment it will be neutralized by attracting opposite polarity charges from t...

Страница 2: ...the filter onto the air intake grill at the back of the ionizer G Power Inlet Connect the power cord here H Fuseholder Stores the 5 A slow blow fuse for powering the ionizer I Ground Terminal For best performance the blower chassis ground terminal and all worksurfaces in proximity to the target i e wokbench ESD mat should always be wired to a reliably earthed electrical point Installation Place th...

Страница 3: ...xtensive maintenance and cleaning beyond that described above NOTE The AC power cord MUST be disconnected before the unit can be disassembled for maintenance First turn the unit OFF and unplug the power cord Unthread and remove 3 Phillips head screws on each side and 2 in rear 8 total The bottom base chassis plate and ionization circuit subassembly can next be separated from the top cover chassis ...

Страница 4: ...e fan speed set to high All measurements are in seconds NOTE Discharge times in seconds are representative only and are not a guarantee Discharge times are actual measurements recorded in a factory ambient environment TP1 60 60 12 12 12 12 12 TP4 60 60 TP7 17 9 23 7 TP10 15 5 16 5 TP2 1 4 1 9 TP5 2 6 3 1 TP8 3 8 4 7 TP11 5 5 6 8 TP3 60 60 TP6 60 60 TP9 60 60 TP12 60 60 Trustat AC Benchtop Ionizer ...

Страница 5: ...ring IEC 320 C14 AC inlet with fuseholder Input Cord NEMA 5 15P to IEC 320 C13 6 ft Input Fuse 5A slow blow Chassis Steel enclosure powder coated epoxy polyester paint finish Air Filter Optional Open cell polyurethan foam 30 pores per in Ozone 0 01 ppm fan LOW 6 in Audible Noise 54 dBA SPL fan LOW 1 ft 61 dBA SPL fan HIGH 1 ft Weight 7 1 lbs 3 2 kg Dimensions with stand knobs 9 x 7 5 x 5 25 229 mm...

Отзывы: