Neutralization (Discharge) Times

All data was taken without an air filter installed and the fan speed set to high. All measurements are in seconds.
NOTE: Discharge times in seconds are representative only and are not a guarantee. Discharge times are actual 

measurements recorded in a factory ambient environment.

TP1

>60
>60

12"

12"

12"

12"

12"

TP4

>60
>60

TP7

+17.9
-23.7

TP10

+15.5
-16.5

TP2

+1.4
-1.9

TP5

+2.6
-3.1

TP8

+3.8
-4.7

TP11

+5.5
-6.8

TP3

>60
>60

TP6

>60
>60

TP9

>60
>60

TP12

>60
>60

Trustat® AC 

Benchtop Ionizer

Air Flow

Charged Plate

12"

Figure 5. Neutralization (discharge) times at 120 VAC, 60 Hz input

Содержание Trustat 19550

Страница 1: ...elds on all process essential insulators if the electrostatic field is considered a threat Air ionization can neutralize the static charge on insulated and isolated objects by producing separate charges in the molecules of the gases of the surrounding air When an electrostatic charge is present on objects in the work environment it will be neutralized by attracting opposite polarity charges from t...

Страница 2: ...the filter onto the air intake grill at the back of the ionizer G Power Inlet Connect the power cord here H Fuseholder Stores the 5 A slow blow fuse for powering the ionizer I Ground Terminal For best performance the blower chassis ground terminal and all worksurfaces in proximity to the target i e wokbench ESD mat should always be wired to a reliably earthed electrical point Installation Place th...

Страница 3: ...xtensive maintenance and cleaning beyond that described above NOTE The AC power cord MUST be disconnected before the unit can be disassembled for maintenance First turn the unit OFF and unplug the power cord Unthread and remove 3 Phillips head screws on each side and 2 in rear 8 total The bottom base chassis plate and ionization circuit subassembly can next be separated from the top cover chassis ...

Страница 4: ...e fan speed set to high All measurements are in seconds NOTE Discharge times in seconds are representative only and are not a guarantee Discharge times are actual measurements recorded in a factory ambient environment TP1 60 60 12 12 12 12 12 TP4 60 60 TP7 17 9 23 7 TP10 15 5 16 5 TP2 1 4 1 9 TP5 2 6 3 1 TP8 3 8 4 7 TP11 5 5 6 8 TP3 60 60 TP6 60 60 TP9 60 60 TP12 60 60 Trustat AC Benchtop Ionizer ...

Страница 5: ...ring IEC 320 C14 AC inlet with fuseholder Input Cord NEMA 5 15P to IEC 320 C13 6 ft Input Fuse 5A slow blow Chassis Steel enclosure powder coated epoxy polyester paint finish Air Filter Optional Open cell polyurethan foam 30 pores per in Ozone 0 01 ppm fan LOW 6 in Audible Noise 54 dBA SPL fan LOW 1 ft 61 dBA SPL fan HIGH 1 ft Weight 7 1 lbs 3 2 kg Dimensions with stand knobs 9 x 7 5 x 5 25 229 mm...

Отзывы: