Block library TeleControl ST7
5.7 Master copies
TIM 1531 IRC
Operating Instructions, 02/2018, C79000-G8976-C468-02
221
Range of
values:
See address range.
Default:
0 (W#16#0)
Address
range:
Output words
QW0 ... QWn
PQW0 ... PQWn
Memory words
MW0 ... MWn
LW0 ... LWn
Data words
DBm.DBW0 ... n
Explanation: Output for a returned setpoint
The partner object receiving the setpoint reports back the currently valid set-
point there. This value is displayed at the "ReturnedSetpoint" output.
If the partner object is set to 'local' and a new input is made there, the setpoint
changed locally is indicated here by "ReturnedSetpoint".
After startup of the local or partner CPU, or after restoring a connection, an
automatic general request ensures that the locally valid setpoint is indicated
by "ReturnedSetpoint".
If you do not require the parameter, simply leave it open.
Parameter: LocalOperation
Declaration: OUTPUT
Data type:
BOOL
Range of
values:
TRUE / FALSE
Default:
FALSE
Address
range:
Output
Q 0.0 ... Q n.7
Memory bit
M 0.0 ... M n.7
L 0.0 ... L n.7
Data bit
DBm.DBX 0.0 ... n.7
Explanation: Return message from the partner object: The object is set to local operation.
A setpoint can also be set locally at the partner object that receives the set-
point. The partner object Set01W_R must then be set to ’local’ at the "Local"
input parameter. The current status of the "Local" input parameter is reported
by the partner object and indicated here at the "LocalOperation" output.
After startup of the local or partner CPU, or after restoring a connection, an
automatic general request ensures that the local currently valid status is dis-
played at "LocalOperation".
If you do not require the parameter, simply leave it open.
Содержание TIM 1531 IRC
Страница 262: ...Block library TeleControl ST7 5 7 Master copies TIM 1531 IRC 262 Operating Instructions 02 2018 C79000 G8976 C468 02 ...
Страница 302: ...Dimension drawings TIM 1531 IRC 302 Operating Instructions 02 2018 C79000 G8976 C468 02 ...
Страница 322: ...Documentation references 13 TIM 1531 IRC 322 Operating Instructions 02 2018 C79000 G8976 C468 02 ...
Страница 336: ...Glossary TIM 1531 IRC 336 Operating Instructions 02 2018 C79000 G8976 C468 02 ...