Range
Return val-
ues
Arguments
a
Us-
able
in
Run
mode
Identi-
fier
Com-
mand
Description
[0, 63],
-
int index
Yes
160
gINT
Get circle edge
contrast
[0, 100]
int contrast
[0, 63],
int index,
No
161
sINT
Change circle dia-
meter thresholds
[1, max]
int min
(
without search
enabled
)
[5, circle within FOV]
b
[0, 1] (0 = pixels, 1 =
millimeters)
int max
int unit
[0, 63],
int index,
No
161
sINT
Change circle dia-
meter thresholds
[shortest search region
side/3, max]
int min
int max
(
with search en-
abled
)
[min, shortest search
region side]
int unit
[0, 1] (0 = pixels, 1 =
millimeters)
[0, 63],
-
int index,
Yes
161
gINT
Get circle diamet-
er thresholds
[0, 1] (0 = pixels, 1 =
millimeters)
-
int min
int unit
Min threshold in the
unit specified,
int max
Max threshold in the
unit specified
[0, 63],
int index,
No
162
sINT
Change circle line
fit criteria
[0, 2] (0 = strongest, 1
= first, 2 = last)
int criterion
[0, 63],
-
int index
Yes
162
gINT
Get circle line fit
criteria
[0, 2] (0 = strongest, 1
= first, 2 = last)
int criterion
[0, 63],
int index,
No
163
sINT
Change circle po-
larity
[0, 2] (0 = any, 1 =
bright to dark, 2 = dark
to bright)
int polarity
[0, 63],
-
int index
Yes
163
gINT
Get circle polarity
[0, 2] (0 = any, 1 =
bright to dark, 2 = dark
to bright)
int criterion
[0, 63],
int index,
No
164
sINT
Change circle ro-
bustness
[0, 4] (0 = high robust-
ness to 4 = high speed)
int robustness
[0, 63],
-
int index
Yes
164
gINT
Get circle robust-
ness
[0, 4] (0 = high robust-
ness to 4 = high speed)
int criterion
8015726/ZPP7/2018-
09
©SICK AG • Identification & Measuring • www.sick.com • All rights reserved
Subject to change without notice
68
Reference Manual
Command channel
Appendix
Inspector PIM
Содержание Inspector PIM60
Страница 1: ...Inspector PIM60 ver 2 0 Vision sensor REFERENCE MANUAL...
Страница 5: ...Introduction...
Страница 7: ...Interfaces...
Страница 38: ...Appendix...
Страница 83: ......