Range
Return values
Arguments
Us-
able
in
Run
mode
Iden-
tifier
Com-
mand
Description
[10,10000]
int
exp*100
No
14
sINT
Change exposure
b
[10, 10000]
int exp*100
Yes
14
gINT
Get exposure
[0, 400]
int gain
No
15
sINT
Change gain
[0, 400]
int gain
Yes
15
gINT
Get gain
0=free-running,
1=trig
int mode
No
16
sINT
Switch trigger
mode(free-running,
trig)
0=free-running,
1=trig
int trigMode
Yes
16
gINT
Get trigger mode
[0, 2],
int index,
Yes
18
sINT
Change value of in-
teger tags in result
output (UINT1-3)
[0,65535]
int value
[0, 2],
int index,
Yes
18
gINT
Get value of integer
tags in result output
(UINT1-3)
[0,65535]
int value
int framePeriod
Yes
19
gINT
Get frame period time
[microseconds]
0=normal mode,
1=calibration
mode
int mode
No
20
sINT
Enter/leave calibration
mode
0=calibration/nor-
mal mode
c
,
int parameterRes-
ult
int paramet-
er
Yes
20
gINT
Get calibration para-
meters
1=calibrated
d
,
2=scaling
e
, 3=ori-
gin
f
, 4=rotation
g
,
5=mean pixel er-
ror, 6=max pixel
error
[0=ms, 1=tick],
[1,50000] resp [0
int type, int
delay (milli-
No
21
sINT
Set external trig delay
ticks, 200000
ticks]
seconds*10
or ticks)
h
[0=ms, 1=tick],
[1,50000] resp [0
int type, int delay
(milliseconds*10
or ticks)
Yes
21
gINT
Get external trig delay
ticks, 200000
ticks]
[0,19], [0=ms,
1=tick], [(Min
int outputIn-
dex, int
No
22
sINT
Set digital output delay
delay
type, int
time)*10,50000]
delay (milli-
resp [0 ticks,
200000 ticks]
seconds*10
or ticks)
[0,19], [0=ms,
1=tick],
int type, int delay
(milliseconds*10
or ticks)
int outputIn-
dex
Yes
22
gINT
Get digital output delay
[1,50000] resp [0
57
©SICK AG • Identification & Measuring • www.sick.com • All rights reserved
Subject to change without notice
8015726/ZPP7/2018-
09
Appendix
Command channel
Reference Manual
Inspector PIM