System Manual V2 – MOVITRAC® B
13
3
Functions / features
System Description MOVITRAC® B
3.4
Functions / features
MOVITRAC
®
B frequency inverters are characterized by the following features:
3.4.1
Unit properties
•
Wide voltage range:
– 230 V units for the voltage range 1 × AC 200 ... 240 V, 50/60 Hz
– 230 V units for the voltage range 3 × AC 200 ... 240 V, 50/60 Hz
– 400/500 V units for the voltage range 3 × AC 380 ... 500 V, 50/60 Hz
•
Overload capacity: 125 % I
N
continuous duty
150 % I
N
for at least 60 s
Maximum 200 % breakaway torque (BG0)
•
Rated operation up to an ambient temperature
ϑ
= 50 °C (122 °F), operation up to an
ambient temperature
ϑ
= 60 °C (140 °F) possible with current reduction.
•
Speed range 0 ... 5500 rpm.
•
Output frequency range:
– VFC: 0 ... 150 Hz
– V/f: 0 ... 600 Hz
•
4-quadrant capability due to the integrated brake chopper.
•
Compact unit design for minimum control cabinet space requirement and optimum
utilization of control cabinet volume.
•
Units with the "Safe stop" function:
– Unit variant (...-S0): 3 × AC 380 ... 500 V, 0.55 ... 4.0 kW (0.74 ... 5.4 HP)
– Standard unit: 3 × AC 380 ... 500 V, 5.5 ... 75 kW (7.4 ... 100 HP)
•
Integrated EMC line filter to maintain the specified limit classes on the line side / C1/
C2 to EN 61800-3:
– Sizes 0 ... 2: C2 without further measures
– Sizes 0 ... 5: C1 with corresponding filters / folding ferrites
•
Configurable inputs / outputs
– 1 analog input
– 6 binary inputs
– 3 binary outputs, including 1 relay output
– Optional: 1 additional analog input / 1 additional analog output
•
Voltage supply and evaluation for TF (PTC temperature sensor) integrated for
monitoring the motor temperature.
•
Integrated evaluation of TH for monitoring the temperature of the motor.