System Manual V2 – MOVITRAC® B
101
5
Explanation of the parameters
Parameters
540
Response to drive vibration /
warning
Factory setting: Display error
Once the drive vibration sensor signals a warning, the inverter will respond with
the set response.
541
Response to drive vibration /
fault
Factory setting: Rapid stop / warning
Once the drive vibration sensor signals a fault, the inverter will respond with the
set response.
542
Response to oil aging / warning
Factory setting: Display error
Once the oil aging sensor signals a warning, the inverter will respond with the
set response.
543
Response to oil aging / fault
Factory setting: Display error
Once the oil aging sensor signals a fault, the inverter will respond with the set
response.
544
Oil aging / overtemperature
Factory setting: Display error
Once the oil aging sensor signals overtemperature, the inverter will respond
with the set response.
545
Oil aging / ready signal
Factory setting: Display error
Once the oil aging sensor signals ready, the inverter will respond with the set
response.
549
Response to brake wear
Factory setting: Display error
Once the brake wear sensor signals a fault, the inverter will respond with the set
response.
6__
Terminal assignment
60_
Binary inputs (DI01 with fixed assignment to CW/STOP)
Effect of
0 signal
1 signal
Takes effect when: No enable
0: No function:
–
–
–
1: Enable / Stop:
Stop at
P136 Stop ramp
Enable
no
2: CW / stop:
Stop at
P131 Ramp down
Enable CW
no
3: CCW / stop:
Stop at
P131 Rampe down
Enable CCW
no
4: n11 / n21
no
5: n12 / n22
no
6: Fixed setpoint switchover:
Fixed setpoints n11/n12/n13
Fixed setpoints n21/n22/n23
yes
7: Parameter set switchover:
Parameter set 1
Parameter set 2
yes
8: Ramp switchover:
t11/t21 active
t12/t22 active
yes
9: Motor potentiometer up:
–
Increase setpoint
no
10: Motor potentiometer down:
–
Decrease setpoint
no
11: /External fault:
External fault
–
no
12: Fault reset:
Reset on positive edge 0 to 1
yes
19: Free-running slave:
Master-slave mode
Free-running slave
yes
20: Setpoint acceptance active:
Do not accept
Accept setpoint
no
26: TF signal (DI05 only):
Motor overtemperature
No signal
no
27: Vibration / warning
Sensor signals warning
Sensor does not signal warning
yes
28: Vibration / fault
Sensor signals fault
Sensor does not signal fault
yes
29: Brake wear
Brake is worn
Brake OK
yes
30: /Controller inhibit:
Inhibited
Enable
yes
33: Oil aging / warning
Sensor signals warning
Sensor does not signal warning
yes
34: Oil aging / fault
Sensor signals fault
Sensor does not signal fault
yes
35: Oil aging / overtemperature
Sensor signals overtemperatureSensor does not signal overtemperatureyes
36: Oil aging / ready
Sensor not ready
Sensor ready
yes
Fixed setpoints
n11/n21 = 0 and n12/n22 = 0:
External setpoints only
n11/n21 = 1 and n12/n22 = 0:
n11/n21
n11/n21 = 0 and n12/n22 = 1:
n12/n22
n11/n21 = 1 and n12/n22 = 1:
n13/n23
601
Binary input DI02
Factory setting: CCW/stop
602
Binary input DI03
Factory setting: Enable
603
Binary input DI04
Factory setting: n11/n21
604
Binary input DI05
Factory setting: n12/n22
608
Binary input DI00
Factory setting: Fault reset
No.
FBG
Name
Description
P
i
f
kVA
Hz
n
Содержание MOVITRAC MC07B0037-2A3-4-00