32
System Manual V2 – MOVITRAC® B
4
Technical data of MOVITRAC® B
Technical Data
4.4.11 AC 230 V / 1-phase / size 0S / 0.55 ... 0.75 kW / 0.74 ... 1.0 HP
MOVITRAC
®
MC07B (1-phase supply system)
0005-2B1-4-00
0008-2B1-4-00
Part number
828 494 6
828 495 4
INPUT
Rated mains voltage
V
supply
1 × AC 200 ... 240 V
Rated mains frequency
f
supply
50 / 60 Hz ± 5%
Rated mains current, 100 % operation
Rated mains current, 125 % operation
I
supply
I
supply 125
AC 8.5 A
AC 10.2 A
AC 9.9 A
AC 11.8 A
OUTPUT
Output voltage
U
A
3 × 0 ... V
supply
Recommended motor power 100 % operation
Recommended motor power 125 % operation
P
Mot
P
Mot 125
0.55 kW / 0.74 HP
0.75 kW / 1.0 HP
0.75 kW / 1.0 HP
1.1 kW / 1.5 HP
Rated output current 100 % operation
Rated output current 125 % operation
I
N
I
N 125
AC 3.3 A
AC 4.1 A
AC 4.2 A
AC 5.3 A
Apparent output power 100 % operation
Apparent output power 125 % operation
S
N
S
N 125
1.4 kVA
1.7 kVA
1.7 kVA
2.1 kVA
Minimum permitted braking resistance value (4
quadrant operation)
R
BW_min
27
GENERAL INFORMATION
Power loss 100 % operation
Power loss 125 % operation
P
V
P
V 125
45 W
50 W
50 W
65 W
Current limitation
150 % I
N
for at least 60 seconds
Terminal cross section / tightening torque
Terminals
4 mm
2
/ AWG12 / 0.5 Nm / 4 lb in
Dimensions
W × H × D
80 × 185 × 163.5 mm / 3.1 × 7.28× 6.437 in
Weight
m
1.5 kg / 3.3 lb
80 (3.1)
163.5 (6.437)
185 (7.28)
196 (7.72)
285 (1
1.2)
70 (2.8)
159.5 (6.280)
149 (5.87)
6 (0.2)
6 (0.2)
220 (8.66)
P
i
f
kVA
Hz
n
Содержание MOVITRAC MC07B0037-2A3-4-00
Страница 250: ......