102
System Manual V2 – MOVITRAC® B
5
Explanation of the parameters
Parameters
62_
Binary outputs
(for controlling the brake
rectifier
use only binary output DO02)
Effect of
0 signal
1 signal
0: No function:
–
–
1: /Fault:
Collective fault signal
–
2: Ready:
Not ready
ready
3: Output stage on:
Unit inhibited
Unit enabled and motor is energized
4: Rotating field on:
No rotating field
Rotating field
5: Brake released:
Brake applied
Brake released (not with DO03)
8: Parameter set:
1 active
2 active
9: Speed reference signal:
n > n
ref
/ n < n
ref
(P403)
n < n
ref
/ n > n
ref
(P403)
11: Set/actual value comparison signal:
n
≠
n
setp
n = n
setp
12: Current reference signal:
I > I
ref
/ I < I
ref
(P433)
I < I
ref
/ I > I
ref
(P433)
13: Imax signal:
I < I
max
/ I = I
max
(P442)
I = I
max
/ I < I
max
(P442)
21: IPOS output:
–
Depends on IPOS program
22: /IPOS fault:
IPOS fault signal
–
23: PI ACTUAL VALUE REF.:
–
PI controller actual value has exceeded the set threshold
24: Ex-e current limit active (in preparation)
27: Safe stop: The display "Safe stop" is
not safety-related
and must not be used as a safety function.
30: /Ixt warning (in preparation)
Normal operation
Ixt > 115 %
31: /Ixt fault (in preparation)
Normal operation
Ixt > 125 %
620
Binary output DO01
Factory setting: /FAULT
621
Binary output DO02
Factory setting: BRAKE RELEASED
622
Binary output DO03
Factory setting: READY (selection 5 (BRAKE RELEASED) not possible)
64_
Analog outputs AO1
(optional)
Analog output AO1 is only available with the optional analog module FIO11B
No.
FBG
Name
Description
Output value
100 % =
–3000 ... 0 ... 3000 rpm
–100 ... 0 ... 100 Hz
0 ... 100 % = 0 ... 150 % I
N
= 0 ... 150 % unit utilization
Normalization
obtained
output value
–100 % ... 0 ... +100 %
AO1
characteristic
curve
Output
0 ... 10 V
0 / 4 ... 20 mA
P
i
f
kVA
Hz
n
Содержание MOVITRAC MC07B0037-2A3-4-00
Страница 250: ......