System Manual V2 – MOVITRAC® B
173
8
Scope of delivery and installation of loose items
Installation
Sizes 4 / 5
Two touch guards with 8 retaining screws are supplied as standard with MOVITRAC
®
sizes 4 / 5. Install the touch guard on both covers of the power section terminals.
Touch guard for MOVITRAC
®
B sizes 4 / 5:
The touch guard comprises the following parts:
The MOVITRAC
®
B unit sizes 4 / 5 can only achieve degree of protection IP10 when the
following conditions are met:
•
Touch guard is fully installed
•
The shrink tubing is installed on all power terminals (X1, X2, X3, X4)
[1] Cover plate
[2] Connection plate
[3] Screen (only for size 4)
[1]
[2]
[3]
NOTE
If the above conditions are not met, MOVITRAC
®
units sizes 4 and 5 have degree of
protection IP00.