System Manual V2 – MOVITRAC® B
217
9
Parameter list
Startup
82_
Brake operation 1 / 2
820 / 821
8607 /
8608
4-quadrant
operation 1 / 2
Off
On
Off
On
83_
Fault responses
830
8609
Response termi-
nal "external fault"
2
4
7
Immediate stop / fault
Rapid stop / fault
(830)
Rapid stop / warning
(833 / 836)
833
8612
Response to RS-
485 timeout
836
8615
Response to
SBus timeout
84_
Reset behavior
840
8617
Manual reset
Yes
No
85_
Scaling actual speed value
850
8747
Scaling factor
numerator
1
... 65535 (can be set with SHELL only)
851
8748
Scaling factor
denominator
1
... 65535 (can be set with SHELL only)
852
8772 /
8773
User travel unit
Text
853
9312
Scaled speed
FBG
0
1
Speed
Scaled speed
86_
Modulation 1 / 2
860 / 861
8620 /
8621
PWM frequency 1
/ 2
4
8
12
16
4 kHz
8 kHz
12 kHz
16 kHz
862 / 863
8751 /
8752
PWM fix 1 / 2
On
Off
On
Off
87_
Process data parameter setting
870
8304
Setpoint descrip-
tion PO1
No function
(factory setting P872)
Setpoint speed
(factory setting P871)
Max. speed
Ramp
Control word 1
(factory setting P870)
Control word 2
Setpoint speed [%]
IPOS PO data
PI controller setpoint [%]
871
8305
Setpoint descrip-
tion PO2
872
8306
Setpoint descrip-
tion PO3
873
8307
Actual value
description PI1
No function
Actual speed
(factory setting P874)
Output current
(factory setting P875)
Active current
Status word 1
(factory setting P873)
Actual speed [%]
IPOS PI-DATA
PI controller actual value [%]
874
8308
Actual value
description PI2
875
8309
Actual value
description PI3
876
8622
PO data enable
No
Yes
No.
FBG
Index
dec.
Name
Range / factory setting
Value
after
startup
Display
MOVITOOLS
®
MotionStudio
0
0
I
Содержание MOVITRAC MC07B0037-2A3-4-00