System Manual V2 – MOVITRAC® B
219
10
Data backup
Operation
10
Operation
10.1
Data backup
10.1.1 Data backup using FBG11B
Use the FBG11B keypad to download parameter data from the MOVITRAC
®
B to the
keypad or copy from the keypad to the MOVITRAC
®
B.
After copying the parameters, check for accuracy.
Data backup using FBG11B
After copying data, the MOVITRAC
®
B is inhibited. The inhibited status is indicated by
a flashing STOP in the status display. The status LED also slowly flashes yellow.
You can revoke the inhibit by taking one of the following measures:
•
Pressing the RUN button on the FBG11B
•
Switching the mains off, waiting 10 seconds, and switching the mains back on
10.1.2 Data backup using DBG60B
Copy the parameter set from MOVITRAC
®
B into the DBG60B keypad. You have the
following options:
•
In the context menu, select the "COPY TO DBG" menu item. Confirm your selection
by pressing OK. The parameter set is copied from MOVITRAC
®
B to DBG60B.
•
In the context menu, select the "PARAMETER MODE" menu item. Select parameter
P807 "MCB
→
DBG". The parameter set is copied from MOVITRAC
®
B to DBG60B.
10.1.3 Data backup using UBP11A
Copy the parameter set from MOVITRAC
®
B to the UBP11A parameter module. To do
so, press the button at the lower end of the module. You need a pointed object for this
purpose.
Enter
Enter
Level 2
out Enter
Select
data backup
Parameter data from
FBG11B
MOVITRAC
®
B
Level 1
Parameter data from
MOVITRAC
®
B
FBG11B
Enter
Start
loading
Enter
Start
saving
Level 3
0
0
I
Содержание MOVITRAC MC07B0037-2A3-4-00
Страница 250: ......