9-13
More precise time unit can be set corresponding to load characteristics as shown below.
In Sinus M, number display is available up to 5. Therefore, if time unit is set to 0.01 sec, Max
Accel/Decel time would be 600.00 sec.
Code
Name
Set
value
Setting range
Description
H71
[Accel/Decel
time scale]
0
0.01~600.00
Setting Unit: 0.01 sec
1
0.1~6000.0
Setting Unit: 0.1 sec
2
1~60000
Setting Unit: 1 sec
Accel/Decel time setting based on Operating Frequency
Group
Code Parameter Name
Setting
Range
Initial
Unit
Drive group
ACC
[Accel time]
-
0 ~ 6000
5.0
Sec
dEC
[Decel time]
-
0 ~ 6000
10.0
Sec
Function group 2
H70
[Frequency
Reference for
Accel/Decel]
1
0 ~ 1
0
Accel/Decel time is set at the
ACC/dEC
.
If you set H70 to 1 {Delta frequency}, Accel/Decel time is the time that takes to reach a
target freq from constant run freq (Current operating freq.).
When H70 and Accel time are set to 1 {Delta frequency} and 5 sec, respectively,
The below graph in Section A shows the change in operating frequency when target frequency is set to
10Hz at first and then changed to 30Hz.
Operating
command
Operating
freq.
5
7
12
Time
[ Sec]
5 sec
5 sec
10Hz
30Hz
Section A
Содержание Sinus M
Страница 10: ......
Страница 15: ...1 5 Notes...
Страница 16: ......
Страница 50: ...6 4 Notes...
Страница 75: ...8 1 CHAPTER 8 CONTROL BLOCK DIAGRAM Frequency setting Drive mode Accel Decel V F control PWM Motor...
Страница 78: ...8 4 Notes...
Страница 114: ...10 14 Normal PID block diagram H54 0...
Страница 115: ...10 15 Process PID block diagram H54 1...
Страница 150: ...10 50 Notes...
Страница 174: ......
Страница 192: ...13 18 Notes...
Страница 204: ......
Страница 208: ...16 4 16 2 Conduit Kit Installation 1 From SINUS M 0001 to SINUS M 0007 2 From SINUS M 0011 to SINUS M 0014...
Страница 217: ...16 13 Model 4000W IP20 A mm B mm L mm H mm P mm 620 600 100 250 40 Overall Dimensions Resistor 4000W IP20...
Страница 219: ...17 1 CHAPTER 17 EC Declaration of Conformity...