9-10
Rotating direction selection via –10 ~ +10[V] input of V1 terminal
Group
Code Parameter Name
Setting
Range
Initial
Unit
Drive group
frq
[Frequency setting]
2
0 ~ 7
0
drv
[Drive mode]
-
0 ~ 3
1
Set
frq
to 2.
Inverter is operating as the table below regardless of Drive mode setting.
FWD RUN Command
REV RUN Command
0 ~ +10 [V]
FWD RUN
REV RUN
–10 ~ 0 [V]
REV RUN
FWD RUN
Motor runs in Forward direction when input voltage to V1-CM is 0~10[V] and FWD RUN command is
active. When input voltage polarity is reversed to –10~0[V] during FWD RUN, motor decelerates to stop
and runs in reverse direction.
When input voltage to V1-CM is 0~10[V] and REV RUN command is active, motor runs in Reverse
direction and if –10~0[V] is entered, the motor rotating direction is reverse.
FX/RX Run Disable
Group
Code Parameter Name
Setting
Range Initial Unit
Drive group
drC
[Direction of motor
rotation select]
-
F, r
F
Function group 1
F1
[Forward/Reverse run
disable]
-
0 ~ 2
0
Select the direction of motor rotation.
0: Forward and Reverse run enable
1: Forward run disable
2: Reverse run disable
Содержание Sinus M
Страница 10: ......
Страница 15: ...1 5 Notes...
Страница 16: ......
Страница 50: ...6 4 Notes...
Страница 75: ...8 1 CHAPTER 8 CONTROL BLOCK DIAGRAM Frequency setting Drive mode Accel Decel V F control PWM Motor...
Страница 78: ...8 4 Notes...
Страница 114: ...10 14 Normal PID block diagram H54 0...
Страница 115: ...10 15 Process PID block diagram H54 1...
Страница 150: ...10 50 Notes...
Страница 174: ......
Страница 192: ...13 18 Notes...
Страница 204: ......
Страница 208: ...16 4 16 2 Conduit Kit Installation 1 From SINUS M 0001 to SINUS M 0007 2 From SINUS M 0011 to SINUS M 0014...
Страница 217: ...16 13 Model 4000W IP20 A mm B mm L mm H mm P mm 620 600 100 250 40 Overall Dimensions Resistor 4000W IP20...
Страница 219: ...17 1 CHAPTER 17 EC Declaration of Conformity...