9-2
Frequency setting via –10 ~ +10[V] input
Group
Code
Parameter Name
Setting Range
Initial
Unit
Drive group 0.00
[Frequency Command]
-
0 ~400
0.00
Hz
Frq
[Frequency Mode]
2
0 ~ 8
0
I/O group
I1
[Filter time constant for negative
input V1]
10
0 ~ 9999
10
I2
[V1 input minimum negative
voltage]
-
0 ~ –10
0.0
V
I3
[Frequency corresponding to I2] -
0 ~ 400
0.00
Hz
I4
[V1 input max. negative voltage] -
0 ~ 10
10.00
V
I5
[Frequency corresponding to I4] -
0 ~ 400
50.00
Hz
I6 ~ I10 [V1 input positive]
Set
Frq
– [Frequency Mode] to 2.
The set frequency can be monitored in
0.00
- [Frequency Command].
Apply –10V ~ +10V signal between V1 and CM terminal.
Output frequency corresponding to –10V ~ +10V input voltage to V1 terminal
V1
CM
When using - 10 ~ 10V from external
circuit
- 10 ~ +10 V
Output freq
(Positive)
Output freq
(Negative)
Input
voltage
0~ 10[ V]
- 10~ 0[ V]
Содержание Sinus M
Страница 10: ......
Страница 15: ...1 5 Notes...
Страница 16: ......
Страница 50: ...6 4 Notes...
Страница 75: ...8 1 CHAPTER 8 CONTROL BLOCK DIAGRAM Frequency setting Drive mode Accel Decel V F control PWM Motor...
Страница 78: ...8 4 Notes...
Страница 114: ...10 14 Normal PID block diagram H54 0...
Страница 115: ...10 15 Process PID block diagram H54 1...
Страница 150: ...10 50 Notes...
Страница 174: ......
Страница 192: ...13 18 Notes...
Страница 204: ......
Страница 208: ...16 4 16 2 Conduit Kit Installation 1 From SINUS M 0001 to SINUS M 0007 2 From SINUS M 0011 to SINUS M 0014...
Страница 217: ...16 13 Model 4000W IP20 A mm B mm L mm H mm P mm 620 600 100 250 40 Overall Dimensions Resistor 4000W IP20...
Страница 219: ...17 1 CHAPTER 17 EC Declaration of Conformity...