8. Glossary
2014-06/5.5C
165
Piranha & QABrowser Reference Manual
energy).
Phantom
In medical radiology, object behaving in essentially the same manner as tissue, with
respect to absorption or scattering of the ionizing radiation in question. Phantom are
used, for example, for simulating practical conditions of measurement:
- for purposes of radiation protection,
- for evaluating the performances to the diagnostic systems with respect to the radiation
or to the object,
- for dosimetry.
Pixel
A two-dimensional picture element in the presented image.
Practical Peak Voltage (PPV)
The PPV is the constant potential producing the same image contrast as the waveform
under test. PPV is defined in the IEC 61676 standard as: "The PRACTICAL PEAK
VOLTAGE is based on the concept that the radiation generated by a high voltage of any
waveform produces the same AIR KERMA contrast behind a specified PHANTOM as a
radiation generated by an equivalent constant potential. The constant potential
producing the same contrast as the waveform under test is defined as PRACTICAL
PEAK VOLTAGE".
Primary protective barrier
See protective barrier
Protective apron
An apron made of radiation absorbing materials, used to reduce radiation exposure.
Protective barrier
A barrier of radiation absorbing material(s) used to reduce radiation exposure.
Protective glove
A glove made of radiation absorbing materials used to reduce radiation exposure.
Rad
The previously used special unit of absorbed dose. It is equal to 100 ergs per gram. 1
rad = 0.01 Gy (10
-2
gray).
Radiation (ionizing)
Any electromagnetic or particulate radiation capable of producing ions, directly or
indirectly, by interaction with matter. Examples are X-ray photons, charged atomic
particles and other ions, and neutrons.
Ripple factor
The variation in the high-voltage expressed as the percentage of the maximum high-
voltage across the X-ray tube during X-ray production: Ripple factor (%) = 100 x (Vmax
- Vmin)/Vmax
Radiation protection survey
An evaluation of the radiation safety in and around an installation, that includes radiation
measurements, inspections, evaluations, and recommendations.
Radiation receptor
Any device that absorbs a portion of the incident radiation energy and converts this
portion into another form of energy which can be more easily used to produce desired
Содержание Piranha
Страница 1: ...Reference Manual English Version 5 5C Piranha QABrowser RTI article number 9629050 10 ...
Страница 8: ...Introduction Chapter 1 ...
Страница 12: ...Description of the Piranha Chapter 2 ...
Страница 29: ...2 Description of the Piranha Hardware and Specifications 2014 06 5 5C 25 Piranha QABrowser Reference Manual ...
Страница 40: ...Description of the QABrowser Chapter 3 ...
Страница 77: ...Measurement Principles Theory Chapter 4 ...
Страница 91: ...Measurements with the Piranha System Chapter 5 ...
Страница 151: ...Optional Accessories Chapter 6 ...
Страница 154: ...6 Optional Accessories Piranha Panoramic Holder Piranha QABrowser Reference Manual 2014 06 5 5C 150 ...
Страница 155: ...Problems and Solutions Chapter 7 ...
Страница 161: ...Glossary Chapter 8 ...
Страница 181: ...Notes Piranha QABrowser Reference Manual 2014 06 5 5C Notes 177 ...