5. Measurements with the Piranha System
Radiography
Piranha & QABrowser Reference Manual
2014-06/5.5C
100
As seen, the measured kVp value is within 0.4 kV for the different total filtration values.
Quick-HVL
If the parameter "
All w. TF+HVL
" is chosen, the QABrowser will display both estimated
total filtration and quick-HVL values for every measurement. Below a sequence of
measurements is shown displaying how the total filtration and HVL can be determined
at three different kV settings with only three exposures:
With the initial exposure the total filtration is displayed (6.8 mm Al) before the kVp is
displayed. Then the measured kVp is shown (117.0 kV) and the estimated total filtration
and HVL are shown as supplementary information. The HVL is calculated to be
6.42 mm Al. The set kV was changed and the Piranha measured 102.6 kV. The HVL is
calculated at 5.70 mm for this kV. The set kV is changed again and a third exposure is
made. The kV is measured to be 83.53 kV and the HVL is calculated to be 4.69 mm Al.
Notice that all three measurements of total filtration were 6.8 mm Al.
Содержание Piranha
Страница 1: ...Reference Manual English Version 5 5C Piranha QABrowser RTI article number 9629050 10 ...
Страница 8: ...Introduction Chapter 1 ...
Страница 12: ...Description of the Piranha Chapter 2 ...
Страница 29: ...2 Description of the Piranha Hardware and Specifications 2014 06 5 5C 25 Piranha QABrowser Reference Manual ...
Страница 40: ...Description of the QABrowser Chapter 3 ...
Страница 77: ...Measurement Principles Theory Chapter 4 ...
Страница 91: ...Measurements with the Piranha System Chapter 5 ...
Страница 151: ...Optional Accessories Chapter 6 ...
Страница 154: ...6 Optional Accessories Piranha Panoramic Holder Piranha QABrowser Reference Manual 2014 06 5 5C 150 ...
Страница 155: ...Problems and Solutions Chapter 7 ...
Страница 161: ...Glossary Chapter 8 ...
Страница 181: ...Notes Piranha QABrowser Reference Manual 2014 06 5 5C Notes 177 ...