3–42 • Operating Instructions
LDP-8242 User Manual (Iss. 03)
(continued)
Short Term Window / Reset Control
Ganged
Short Term Window
control for
Meter 1
and
Meter 2
sets the
duration (in seconds) that sampling time accumulates before each
averaging recalculation (see below)
(0.1 to 60.0 seconds range in 0.1-second steps; default = 1.8 sec)
Reset button clears the accumulated moving average data, and restarts
measurement.
In this example, the last 3 measurement periods are averaged in each reported LUFS value. This cycle is continually
repeated. The
Measurement Window
parameter sets the sampling time accumulated before each averaging
recalculation.