Extended Analog Input EAI
Fig. 7-38:
EAI analog input
Code
Name
Setting Range
Default
Attri.
H8.05
EAI input mode
0: 0...20 mA
1: 4...20 mA
2: 0...10 V
3: 0...5 V
4: 2...10 V
5: -10...10 V
0
Stop
F2.02
Extended analog input EAI
0: No function assigned
1: Pressure command
2: Pressure feedback
3: Oil level warning / error
4: Oil temperature
0
Stop
F2.04
Pressure command corresponding to 10 V / 20
mA
0.1...1,000.0 bar
100.0
Stop
F2.05
Pressure command null offset in V or mA
0...5.0 V, mA
0.1
Stop
F2.06
Pressure feedback corresponding to 10 V or 20
mA
0.1...1,000.0 bar
100.0
Stop
F2.07
Pressure feedback null offset in V or mA
0.0...5.0 V, mA
0.1
Stop
Tab. 7-21:
Analog input AI2 parameter list
DOK-SYTROX-DRN5020****-IT05-EN-P
Bosch Rexroth AG
99/143
Frequency-Controlled Pump Drive System Sytronix DRn 5020
Commissioning of Sytronix DRn 5020 System