7.2.5
Relevant Parameters
Code
Name
Code
Name
C0.00
Control mode
(EFC 5610 only)
F2.31
AO1 output (use E2.27 for gain)
C1.05
Motor rated power
F2.36
DO1 output
C1.09
Motor rated speed
F2.37
EDO output
D0.81
Effective pressure command value
F2.40
Relay 1 output
E0.08
Maximum output frequency
F2.41
Extension relay output
E0.09
Output frequency high limit
F3.12
Speed adaptation: P-gain
E0.26
Acceleration time
F3.13
Speed adaptation: I-gain
E0.27
Deceleration time
F3.16
Speed adaptation: D-gain
E1.00
X1 input
F3.19
Speed adaptation: Minimum speed
E1.01
X2 input
F3.20
Speed adaptation: Maximum speed
E1.35
AI1 input mode
F3.21
Speed adaptation: Ramp pitch, ascending
E1.40
AI2 input mode
F3.22
Speed adaptation: Ramp pitch, descending
E2.15
Relay1 output selection
F3.23
Speed boost: Ramp pitch
E2.25
AO1 output mode
F3.24
Speed boost: Pressure window
E2.26
AO1 output setting
F3.25
Speed boost: Wait time
E5.15
Sleep level
F3.26
Pressure command value: Trigger level
E5.16
Sleep delay
F3.27
Pressure command value: Learning window
E5.17
Sleep boost time
F3.28
Pressure command value: Learning time
E5.18
Sleep boost amplitude
F3.29
Start-up time
E5.19
Wake up level
F4.00
Protection function control word
E5.20
Wake up delay
F4.29
Pump type
F1.00
ASF parameter initialization
F4.30
Pump: Maximum displacement
F1.02
Control word: Pressure command source
F4.35
Pump power
F1.04
Pressure command selection
F4.50
Pump: Maximum angular acceleration
F1.05
Pressure command digital setting 0
F4.51
Pump: Maximum speed
F1.06
Pressure command digital setting 1
F4.52
Pump: Minimum speed
F1.08
Preferred swivel angle command source
F4.53
Pump: Inertia mantissa
F1.09
Command value: Preferred swivel angle
F4.54
Pump: Inertia exponent
F1.15
Motor type
F4.55
Motor derating: Continuous torque at standstill
F1.16
Motor power level
F4.56
Motor derating: Limit speed
F2.00
Analog input AI1
F4.57
Speed masking: Center speed
F2.01
Analog input AI2
F4.58
Speed masking: Window
F2.02
Extended analog input EAI
F4.59
Auxiliary pump: Displacement
DOK-SYTROX-DRN5020****-IT05-EN-P
Bosch Rexroth AG
95/143
Frequency-Controlled Pump Drive System Sytronix DRn 5020
Commissioning of Sytronix DRn 5020 System